23
PB
OPERATION
Dehumidifying mode
The dehumidifying mode is illustrated as follows:
Dehumidifying area I: Operation at the frequency in the range (30–60Hz) according to Dt (Tindoor ambient-Tset).
Dehumidifying area II: The compressor stops for 5 minutes and operators for 5 minutes at the lowest frequency.
Dehumidifying area III: The compressor stops.
Dt(°F)
f(Hz)
32
30
33
30
34
40
35
50
36
60
Figure 304
Figure 305
62˚F