PHYSICAL INSTALLATION
Conduit Box Installation
25
4. Install the conduit box to the drive using the following screws and nuts tightened to a torque of:
M6 Screws 1 - 6: 55-65 kg-cm / 47.7-56.4 Ib-in / 5.4-6.4 Nm
M8 Screws 7 - 9 and Nuts 14 - 17: 100-110 kg-cm / 86.7-95.4 Ib-in / 9.8-10.8 Nm
M10 Nuts 10 - 13: 250-300 kg-cm / 216.9-260.3 Ib-in / 24.5-29.4 Nm
5. Replace the covers and screws removed in Step 1
to the original locations. Tighten to a torque of
35-45 kg-cm / 30.3-39 Ib-in. / 3.4-4.4 Nm.