Connecting the internal power supply
Connect connecting cable (2) to electronic
unit (1)
Plug connector of connecting cable (2) on
rear panel of machine, as illustrated
3.1.5.
Commissioning
•
Caution! If the red LED is lit, check the following:
-
Is the electronic unit correctly in place in the water tank?
-
Water level (water level must not exceed half the water tank.)
-
Scale build-up of the electronic unit; de-scale if necessary
Process
Response of the LED on the electronic
unit
A
The microswitch opens the valve of the
electronic unit.
LED off
B
The water tank fills up with water and
the operating float switches the valve
off once the level is reached.
LED off
C
If the operating float jams, e.g. due to
scale build-up, the water level
continues to rise until the safety float
switches the valve off.
LED on
(1)
(2)