46
E046 chipcard read
CRC error main ID block.
47
E047 chipcard read
CRC error only shadow ID block.
48
E048 chipcard read
CRC error in two data blocks
(main block + mirrored).
49
E049 chipcard read
CRC error in a data block (mirrored).
50
E050 chipcard read
Error reading the header information.
Either the contacts of the chip or of the reader are
soiled or the card is defective. It may be necessary to
re-initialise.
51
E051 chipcard ident
Invalid manufacturer’s code. (RID code invalid.)
Card cannot be used on the Evolution.
52
E052 chipcard ident
Invalid manufacturer’s code. (PIX code invalid.)
Card cannot be used on the Evolution.
53
E053 chipcard ident
Card type is not supported by Evolution.
54
E054 chipcard ident
Error reading the data block. Either the contacts of the
chip or of the reader are soiled or the card is defective.
It may be necessary to re-initialise.
55
E055 chipcard ident
The installation number is incorrect and is for a
different device.
57
E057 chipcard write
Card has become unusable because no error counter
bits are available (max. 8).
58
E058 chipcard write
A card with an incorrect write-protection code is in the
reader. Warning! After 8 attempts to read the card, it
will become irrevocably unreadable (error 57).
59
E059 chipcard write
A timeout occurred while writing to the card. Either the
contacts of the chip or of the reader are soiled or the
card is defective. It may be necessary to re-initialise.
Summary of Contents for Flair
Page 2: ......
Page 4: ......
Page 6: ......
Page 22: ......
Page 76: ......
Page 77: ...TD 100350 doc ...
Page 78: ......
Page 79: ...TD 100351 doc ...
Page 80: ......
Page 81: ...TD 100352 doc ...
Page 82: ......
Page 84: ......
Page 86: ......
Page 88: ......
Page 114: ......
Page 116: ......
Page 120: ......
Page 126: ......
Page 128: ......
Page 138: ......
Page 139: ...Franke Kaffeemaschinen AG TD 100470 doc 1 32 Operating Instructions for Inkasso3 ...