TD-100343.doc
45
4.12. Thermal link
4.12.1. Mode of operation
The thermal link protects the thermoblock from overheating and switches the heating off.
4.12.2.
Replacing the thermal link for coffee/hot water and steam
Removing the thermal link
•
CAUTION! The thermal links are not
interchangeable!
Unscrew screw from retaining clamp
Remove link and replace
Installing the thermal link
Place thermal link exactly in positon under
the retaining clamp
Tighten screw
4.12.3. Technical data
Principle:
Safety fuse
Coffee/hot water thermal link
184° C (363° F) (230 V)
Steam thermal link:
216° C (421° F) (230 V)
Hot water
Steam
Summary of Contents for Flair