Franke Kaffeemaschinen AG
TD-100356.doc
25 / 32
Diagnosis with Terminal 3000
As with the diagnosis using Franke Service Animation, the diagnosis here is also divided into
two parts: the “History bits” (Entry diagnosis) and the “Service stamp” (Exit diagnosis).
Important:
Both diagnoses must be performed; otherwise the diagnosis document
cannot be created.
Perform Entry and Exit diagnoses
Switch on the terminal using the “ON/OFF” button.
Enter date
D:02 M:02 Y:2005
Confirm each entry of the date with the ENTER key or enter a new date with the numerical
keypad.
Enter time
H:14 M:25 S:24
Confirm each entry of the time with the ENTER key or enter a new time with the numerical
keypad.
Terminal ready
Data loaded
Now press the “History bits” key
Please wait
Coffee
à
Terminal
Terminal ready
Data is loaded
Use the arrow keys to view any occurring errors.
History bits
0 Encoder
no encoder signal
0 Coffee sensor
unit heater sensor for coffee defective
0 Steam sensor
unit heater sensor for steam / hot water defective
0 Decalcification
decalcification aborted
0 Position
brewing assembly position cannot be reached
0 Initialisation
initialisation not possible
0 Fluid system
flow meter timeout although tank float responds
0 = no error 1 = error
If no errors have been output, you can perform the Individual test.
Press the “Individual functions” key. You can check the individual functions as described in the
Terminal 3000 instruction manual in the section “Individual test”.
For example: F01 device ON
Summary of Contents for Flair
Page 2: ......
Page 4: ......
Page 6: ......
Page 22: ......
Page 76: ......
Page 77: ...TD 100350 doc ...
Page 78: ......
Page 79: ...TD 100351 doc ...
Page 80: ......
Page 81: ...TD 100352 doc ...
Page 82: ......
Page 84: ......
Page 86: ......
Page 88: ......
Page 114: ......
Page 116: ......
Page 120: ......
Page 126: ......
Page 128: ......
Page 138: ......
Page 139: ...Franke Kaffeemaschinen AG TD 100470 doc 1 32 Operating Instructions for Inkasso3 ...