TD-100347.doc
84
8.3. Service
8.3.1.
Service instructions for the brewing unit
•
Rinse brewing unit under warm flowing water only.
•
Replace drain valve, by not current version of the drain valve or by out of order.
•
Allways replace piston o-ring.
Service periode
We recommend the following service intervals for the Flair brewing unit when it is used
under regular conditions:
> 15,000 cycles
replace brewing unit
> 3 years, < 15,000 cycles
replace brewing unit
< 3 years, < 15,000 cycles
Service for brewing unit, see Chap. 4.5.
Service spare parts
Part no.
Description
Notes
1P 315 415
Replacement drain valve complete V2
1T 310 382
Piston o-ring
BK 301 313
Klueber Microlube GBU Y131
Collapsible tube
1L 296 804
Kluebersinth UH1 64-2403
Collapsible tube