8.2. Fault messages on the display (history bits)
Sensor = temperature sensor
Error code
Cause
Measures
2
Coffee / hot water sensor defective
Replace sensor
4
Steam sensor defective
Replace sensor
8
Initialisation not possible or minimum
brewing unit length not reached
Check piston O-ring and replace
The error bit will be cleared in the service. (Only can be read out on the Terminal3000).
•
N.B. Faults 2 and 4 can occur at temperatures below 10° C (50° F) and above 180 °C
(356° F) as the sensor value is outside the admissible tolerance. The fault message
disappears once the temperature is back within the normal range.
History bits
The Terminal3000 is capable of recognising the
History Bits
recorded by the Flair coffee
machine. The digit 0 or 1 in front of the text indicates whether or not there is a fault.
0 = History bits not set (no error)
1 = History bits set (error)
Terminal display
(history bits)
Cause / Error
Measures
ENCODER
No encoder signal (channel error)
Check cables, plug-in connections
and encoder; replace if necessary
COFFEE SENSOR
Sensor for coffee/hot water unit heater
defective
Check cables, plug-in connections
and sensor; replace if necessary
STEAM SENSOR
Sensor for steam unit heater defective
Check cables, plug-in connections
and sensor; replace if necessary
DE-SCALING
De-scaling aborted
POSITION
Position cannot be reached
Check brewing unit with drive and
encoder
INITIALISE
Initialisation not possible
FLUID SYSTEM
Flowmeter timeout even though tank float
responds
Check flowmeter
Summary of Contents for Flair
Page 2: ......
Page 4: ......
Page 6: ......
Page 22: ......
Page 76: ......
Page 77: ...TD 100350 doc ...
Page 78: ......
Page 79: ...TD 100351 doc ...
Page 80: ......
Page 81: ...TD 100352 doc ...
Page 82: ......
Page 84: ......
Page 86: ......
Page 88: ......
Page 114: ......
Page 116: ......
Page 120: ......
Page 126: ......
Page 128: ......
Page 138: ......
Page 139: ...Franke Kaffeemaschinen AG TD 100470 doc 1 32 Operating Instructions for Inkasso3 ...