TD-100345.doc
73
6.6. Working with Terminal3000
Diagnostics with Terminal3000
The diagnosis is split into 2 areas, in <<history bits>> (input diagnosis) and in <<service
stamp>> (output diagnosis), the same as in the Franke Animations application.
Performing input and output
1.
Switch the terminal on using the "ON/OFF" button.
<<Enter date>>
<<D:02 M:02 Y:2001>>
2.
Enter the date with the numeric keyboard and confirm each entry with <<Enter>>.
<<Terminal ready>>
<<Data loaded>>
3.
View data with <<history bits>>
<<Please wait>>
<<Coffee->terminal>>
<<Terminal ready>>
<<Data loaded>>
4.
Use the cursor keys to view all possible errors.
History bits
Perform the single test even though no error message has been displayed.
By that, all components can be checked up on their proper function.
Error code
Screen Terminal (history bits)
Cause / occurred mistake
0
ENCODER
No encoder signal (Channel Error)
0
COFFEE SENSOR
Sensor thermoblock coffee / hot
water defect
0
STEAM SENSOR
Sensor thermoblock Steam defect
0
DE-SCALING
De-scaling cancelled
0
POSITION
Position failed
0
INITIALISATION
Initialisation failed
0
FLUID SYSTEM
Flowmeter timeout, although tank
float responds.
Summary of Contents for Flair
Page 2: ......
Page 4: ......
Page 6: ......
Page 22: ......
Page 76: ......
Page 77: ...TD 100350 doc ...
Page 78: ......
Page 79: ...TD 100351 doc ...
Page 80: ......
Page 81: ...TD 100352 doc ...
Page 82: ......
Page 84: ......
Page 86: ......
Page 88: ......
Page 114: ......
Page 116: ......
Page 120: ......
Page 126: ......
Page 128: ......
Page 138: ......
Page 139: ...Franke Kaffeemaschinen AG TD 100470 doc 1 32 Operating Instructions for Inkasso3 ...