Faults and warnings
93
9.1.6
Water meter
If the rod electrode is grounded when water is dispensed but the water meter sends out no
pulse,
Fault, water meter
will appear in the display.
Feeder operation can be continued in emergency mode.
You start emergency mode as follows:
1. Confirm
Fault, water meter
by choosing
.
2. Confirm
Bo. water start?
by choosing
.
3. Check whether pulses are shown in the display.
4. Confirm
Mixer: draining?
by choosing
.
5. Confirm
Delete fault?
by choosing
.
6. Confirm
emergency mode start?
by choosing
.
Warning, water meter will appear in the display. The calibration values for the water boiler
become invalid.
7. Calibrate the boiler water.
The automatic feeder will operate in emergency mode, the error message
Calibr. Bo. wa-
ter
will disappear
You can correct the fault as follows:
1. Repair or replace the water meter if necessary.
2. Delete the
water meter warning
.
You will see the fault message
Calibr. Boiler water
in the display.
3. Calibrate water.
4. Return to automatic mode.
9.1.7
Emptying the mixer
Fault, mixer draining
will appear if the mixer cannot be drained.
Feeder operation will be interrupted. Make sure that the end user provides the calves with feed
using an alternative method as long as feed operation is interrupted.
DANGER!
Fatal electric shock.
The electrical components of the automatic feeder are live.
►
Always switch off the automatic feeder firstly with the Main switch and then disconnect the
power plug before working on components of the feeder.