116
Appendix
Configure single IFS feeding box(es) / set extras, if any.
For IFS feeding box(es), assign CAN bus addresses: To do this, put IFS (feeding box)
into search mode and then, via search? assign the address.
Configure quadruple IFS feeding box(es) and issue CAN bus addresses: To do this,
put compact IFS unit into search mode and then allocate address via
search?
assign
the address.
For each of the four pumps, enter the assignment to the station and its equipment.
Configure the CalfRail and issue a CAN bus address: To do this, put CalfRail unit into
search mode and then, allocate address via
search?
assign the address.
Configure IFS concentrate station 1(...). Select concentrate feeder type. Issue CAN
bus addresses: To do this, put IFS (C-station) into search mode and then, via
search
?
assign the address.
Configure scales controller(s) 1/x. To do this, set the CAN address on the scales con-
troller circuit board via HEX switch and enter the set address in setup. Activate any
weighing units (1/2).
Terminal
:
Assign address.
Communication
:
Institute yes/no
Printer no/serial/CAN.
Configure gateway, parameters.
Configure network.
Device data
OK?
Operating modes:
Set rationed or ad lib mode.
Set portion:
Set the set and minimum temperature.
Set output pause.
Set mixer draining and mixer OFF delay
Check
time and date
.
Assign the
function keys
Specify the
animal list
.
Define the station parameters:
Drain time.
Switch
auto-calibration
on or off, specify the time of auto-calibration.
Teat slider
(close/open after xx min).