Commissioning
3.6.4
Connecting the Ethernet cable
Connect the Ethernet cable as follows:
1. Remove the dummy plug on the feeder housing.
1 Dummy plug
2. Open the left side door of the automatic feeder.
3. Remove the cylinder with the Ethernet connection from the bracket on the feeder housing.
1 Cylinder with Ethernet connection
4. Remove the plugs from the seal and open the screw connection of the cylinder.
1 Seal in cylinder
5. Remove the cable sleeve from the cylinder and attach it at the location of the dummy plug
in the feeder housing.
6. Guide the end of the unattached Ethernet cable through the cable sleeve.
7. Screw on the other end of the cylinder and pull out the socket and the Ethernet cable of the
automatic feeder.
1
1