48
7-5-3. Direct Pattern Function
Direct pattern is a function that enables WIPE patterns and DVE patterns to be stored to the
0 to 9 buttons on the keypad for direct recall. Up to 10 direct patterns each can be stored for
the WIPE patterns and DVE patterns, for a total of 20 patterns. The SHIFT button is used to
switch between WIPE and DVE patterns. Frequently-used WIPE patterns and DVE patterns
can be stored as direct patterns for operating convenience.
Storing direct patterns
Press the DIRECT PATT button on the keypad. The keypad changes to direct pattern
mode, and then the DIRECT PATT button, STORE button, and the 0 to 9 buttons where
direct patterns are already stored light up.
The WIPE PATTERN list is displayed in the menu screen. To switch to and display the
DVE PATTERN list, press the SHIFT button.
Press the button (0 to 9) where you want to store the pattern while holding down the
STORE button on the keypad.
Turn the F5 control in the direct pattern select menu in the menu screen to select the
pattern to store. To move between pages, turn the press the UP/DOWN button or turn the
F5 control while holding it down. Pressing the F5 control stores the selected pattern to a
button on the keypad.
Selecting direct patterns
Press the button to select the bus that you want to use in the NEXT TRANSITION section
of the transition section.
Press the DIRECT PATT button on the keypad.
The icon for the stored WIPE direct pattern is displayed in the menu screen. Each icon
corresponds to one of the 0 to 9 button on the keypad. Press the keypad button
corresponding to the pattern that you want to use. The pattern is selected, and the bus
changes to WIPE type.
IMPORTANT
To switch to and select a DVE pattern, press the SHIFT button.
SEQ
EVENT
DVE CH
DIRECT PATT
7
4
1
0
8
5
2
CLEAR
(CANCEL)
9
6
3
SHIFT
STORE
RECALL
+/-
ENTER
(PLAY)
(PAUSE)