19-3. Network Settings
19-3-1. Arcnet (Option)
To connect the MU and the OU using an Arcnet, an Arcnet option board is required for the
MU and the OU respectively. Consult your dealer for more details.
OU and MU are configured for ARCNET as below
For the MU and OU to communicate, use the BNC cable to connect an Arcnet port of each
unit. If you want to connect other devices to the Arcnet, use the other Arcnet port of the MU or
the OU. If the MU or the OU is the last device in the network, the other port has to be 75 ohm
terminated. Refer to section 3-2 “Optional Configuration" for Arcnet configuration and
operation manual for HVS-AUX16/32 (Hanabi Auxiliary unit).
Arcnet Setting
Press STATUS(SETUP) button with SHIFT button lit in the menu select section to open
the SYSTEM top menu.
Turn F1 to select NETWORK and press F1 or the DOWN button to open the
SETUP-NETWORK menu.
The factory default settings for the ARCNET are shown in the table below. Change
ARCNET settings only when if necessary. If the MU ID or OU ID is changed, press
ENTER in the keypad to confirm the setting.
Parameters
Description
Default
Setting
Range
OU
Sets Arcnet ID for the OU (if Arcnet option board
is installed to the OU).
1 1-255
CTRL
Selects MU Arcnet ID controlled by the OU (if
Arcnet option board is installed to the OU).
250 1-255
CTRL MU
Selects which port is used when controlling MU.
D-sub
D-sub,
Arcnet
MU
Sets Arcnet ID for the selected MU (if Arcnet
option board is installed to the MU).
250 1-255
Accessible MU ID(s) will be shown under the ACTIVE MU ID item in the menu. If you want to
disconnect the MU from the OU on the Arcnet, select any ID other than shown in the ACTIVE
MU ID block.
IMPORTANT
To configure an Arcnet connection, an optional Arcnet board is required for the MU
and the OU respectively. If any Arcnet boards are not installed, Arcnet setting
parameters will not be displayed in the SETUP-NETWORK menu.