www.fmiproducts.com
125898-01D
31
Manual Mode
Push MODE button for manual ON, the
The second push of the MODE button will
put the control into the THERMO mode. You
can continue to push the MODE one more
time to OFF.
Note: The MODE button will operate
ON - THERMO - OFF in a series that will cycle
from ON to THERMO to OFF.
The control of the lighting output will be from
a button on the handheld transmitter. When
the LIGHT button is pressed, the LIGHT set-
user can select desired setting from highest
to lowest with 6 different levels to the lighting
output via the UP and DOWN buttons. If no
control will exit the function setting mode and
the LCD display will return to the normal view.
The lights are completely independent of
user can turn the lighting output ON or OFF
no effect on the lighting output.
The lights will be controlled with a separate
module that will plug into the main control
module with AUX communication port. This
4-pin system should control all the 120VAC
components. The 120VAC plug in module
will have two wires that are for the lighting
and they should be 18 AWG 105C wires with
1/4" insulated connectors two males that will
be two wires, length 6 "to 8" coming from the
120VAC module. The AC Neutral wire will be
white and the AC Hot wire will be red. This
is outlined within a separate section.
100%
5
90%
4
80%
3
70%
2
60%
50%
Off
0%
Continuous Pilot
Operation of this feature of having the pilot
to run all the time will be activated with the
pressing of two buttons, "PROG/TIME" &
"FLAME 1". This action will activate the Icon
on the LCD screen. Pressing of the same two
buttons will de-activate the feature.
This feature is the same as the standard AF-
4000 module, but activation of the system
is different in that two buttons must be de-
pressed to activate or de-activate the function.
This feature can also be activated via a 2-posi-
tion switch on the side of the main module.
Main Flame Modulation
motor on the main gas valve.
from a button on the handheld transmitter.
When the FLAME MAIN button is pressed,
LCD display and the user can select desired
setting from highest to lowest with 6 different
levels via the UP and DOWN buttons. If no
control will exit the function setting mode and
the LCD display will return to the normal view.
To allow for proper burner ignition the main
the highest. After 5 seconds that system will
turning off. This will have to be in all modes of
the operation, Manual, Thermo, and Program.
Countdown Timer
The timer function is like the 1001LCD in that
you will have up to 3 hours of countdown time
both Manual and Thermal modes.
Once you have pressed the timer button the
at 10 minutes as the start point. The user can
change the time from 10 minutes to 180 minutes,
within 7 seconds, the control will accept the 10
minute setting, exit the function setting mode, and
the LCD display will return to the normal view.
Pushing "TIMER" button, you can set the
clock area.
You can press the "up" or the "down" to set
your desired TIMER segment.
GAS CONTROL MODULE SYSTEM
Continued