background image

Read, understand and follow 
these instructions for safe 
installation and operation. 

Improper installation, adjustment, alteration service 
or maintenance can cause injury or property dam-
age. 

Read the installation and maintenance instructions 
thoroughly before installing or servicing this equip-
ment. 

!

 

WARNING

 

If the information in these instructions is not 
followed exactly, a fire or explosion may result 
causing property damage, personal injury, or 
loss of life.

 

• 

Do not store or use gasoline or other flammable 

vapors and liquids in the vicinity of this or any other 
appliance. 
• 

What to do if you smell gas: 

-

 Do not try to light any appliance. 

- Do not touch any electrical switch. Do not use any 
phone in your building. 

- Immediately call your gas supplier from a neigh-
bor’s phone. Follow the gas supplier’s instructions. 

- If you cannot reach your gas supplier, call the fire 
department. 

• Installation and service must be performed by a 
qualified installer, service agency, or the gas suppli-
er. 

!

 

WARNING

 

Installation and service of this appli-
ance should be performed by qualified 
personnel. CabanaCoast

®

 suggests NFI 

certified or factory-trained 

professionals, or technicians super-
vised by an NFI certified professional. 

It

'

s imperative the burner be kept clean. 

!

 

WARNING

 

For outdoor use only. 

!

 

WARNING

 

HOT! DO NOT TOUCH. SEVERE BURNS MAY RESULT. 

CLOTHING 

MAY CATCH FIRE

.

 

Glass and other surfaces are hot during 
operation and cool down. 

• Keep children away. 

• CAREFULLY SUPERVISE children near or around 
this appliance. 

• Alert children and adults to hazards of high tem-
peratures. 

• Keep clothing, furniture, draperies and other com-
bustibles away. 

!

 

WARNING

 

DO NOT DISCARD THIS MANUAL 

Important operating                
and maintenance 
instructions included. 

CAUTION

 

DO

 N

OT

 

DI

SCAR

User Manual for: 

CB-20, CB-1224, CB-1242, CB-2424

 

CabanaCoast® Fire

 Natural Gas Installation

 

(Conversion kit required) 

www.CabanaCoast.com 

Summary of Contents for CB-1224

Page 1: ...our gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas suppli er WARNING Installation and service of this appli ance should be performed by qualified personnel CabanaCoast suggests NFI certified or factory trained professionals or technicians super vised by an NFI certified professional It s imperative the burner be k...

Page 2: ...ons ANSI Z21 97 2014 CSA 2 41 2014 Decorative Outdoor Gas Fire Fire Pit CABANACOAST Actiwin Company Limited Mississauga ON CANADA __________________________________________________________________________________________________________ CabanaCoast Firepit Series No Model 50 x32 Firepit Type Natural gas or Propane Gas ORIFICE SIZE NG 31 LPG 43 Min Gas supply for input Adj Max Inlet Supply Pressure...

Page 3: ...the Appliance 11 Reference Materials A Service Parts List B Contact Information C Limited One Year Warranty What s included CB 20 CB 1224 CB 1242 CB 2424 20 Round burner Black propane hose with regulator Flexible metal gas line Valve Assembly Piezoelectric igniter requires 1 AA battery 43 Orifice LP 31 Orifice NG 2 bags of decorative glass 12 x24 burner Black propane hose with regulator Flexible m...

Page 4: ...for Outdoor Gas Fire places and has been listed by CSA Group for in stallation and operation as described in these instal lation and operating instructions The installation must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z21 97 2014 CSA 2 41 National Gas Installation Code Propane Installation Code B BTU Specifications LP NG CB 20 43 31 Max input ...

Page 5: ...ls See sections 3 7 B Tools and Supplies Required Before beginning the installation be sure that the fol lowing tools and supplies are at hand Gloves Safety Glasses Phillips screwdriver Non corrosive leak check solution Wrenches 1 AAA battery Asphyxiation Risk This gas appliance is for outdoor use in a well ventilated space This unit must not be installed inside an enclosed structure or unvented a...

Page 6: ...PURPOSES ONLY Illustrations diagrams are not drawn to scale Actual installation may vary due to individual de sign preference 72 inches to overhang from top of metal bowl If you are not using a CabanaCoast Fire Pit table with this fire pit table be sure to mount to a non combustible surface maintaining at least 8 to combustible surfac es and framing below the surface of burner Figure 3 1 Clearance...

Page 7: ...m If ventilation openings at floor lev el are in a side wall there must be a least two open ings The bottom of the openings must be at floor level and the upper edge can t be more than 5 in 127 mm above the floor The openings must be equally sized spaced at 180 degrees 3 14 rad and unobstructed Every opening must have minimum dimensions to permit the entrance of a 1 8 inch 3 2 mm diameter rod Acce...

Page 8: ... burner area Use all glass provided for best effect Keep glass clear of igniton electrode to avoid accidental blockage Note A percentage of glass beads may arrive split in half This is normal Additional beads may split after use This is also normal due to the physical properties of glass LP Gas Models Make sure the tank valve is turned completely off clockwise Ensure the tank valve has the proper ...

Page 9: ...nual can be purchased to relo cate the grounding contact point of this igniter to a nearby metal surface Once properly grounded located the black wire hang ing from your burner and insert it into the port on the back side of the igniter Style B two prongs externally grounded This igniter relies on external grounding for proper op eration A thin surface is required for mounting such as an CabanaCoa...

Page 10: ... by a qualified installer ap proved and or licensed as required by the locality In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter Note A listed and Commonwealth of Massachusetts approved 3 8 in T handle manual shut off valve and flexible gas connector are connected to the 3 8 in control valve inlet If substituting for these components please co...

Page 11: ...th this burn er 2 Attach the propane hose to incoming gas fitting on the gas valve For CabanaCoast gas valves and control panels this is the lower fitting Using two wrenches one to hold the valve and one to turn the valve fitting Tighten securely 3 Locate the metal flex line gas hose and tighten securely to the top valve fitting following the method described in step 2 4 Using two wrenches securel...

Page 12: ...ded metal flex line hose and thread one end onto orifice and tighten securely with two wrenches 3 At this point if you are connected to natural gas using a valve assembly such as The CabanaCoast valve kit proceed to step 3a 3a Attach the free end of flex hose to the top outgoing flare fitting of control valve and tight enfully with two wrenches Plumb incoming nat ural gas to the incoming side of t...

Page 13: ...P i t C o n t r o l P a n e l a n d G a s V a l v eA s s e m b l y Wh a t s l n c l u d e d C o n t r o l K n o b G a s V a l v e S c r e w s 2 C A B A N A C O A S T R e q u i r e d t o o l s P h i l i p s s c r e w d r i v e r ...

Page 14: ...ttempted repair may result in a fire or explosion D Do not use the appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and replace any part which has been underwater E The gas pressure regulator provided with this appli ance must be used This regulator is set for an outlet pressure of 10 5 inches water column Lighting Instructions 1 D...

Page 15: ...r vapors may ignite WARNING 7Finishing If only a CabanaCoast burner was purchased personalize your Fire Pit with noncombustable decorative items such as bricks landscaping blocks or rocks CabanaCoast also sells a variety of fire pit tables to fit each of our burners as shown below not all models shown Discover more at CabanaCoast com 30036M 4202 Mesa 42 Round 30036 48 48 Round Hampton Firepit 3003...

Page 16: ...duced by a furnace or heating duct This noise does not affect the operation or longevity of the appliance A Heat and or abrupt temperature changes A Piezoelectric Igniter is improperly grounded B Ignition or ground wire not plugged in C Igniter tip set too far from rounding probe Check the LP propane tank You may be out of gas Or check Natural Gas valve at main Check the burner orifice for stoppag...

Page 17: ...orative glass and examine burner Vacuum and wipe out as needed Use caution when cleaning these areas 2 Inspect for warping and corrosion Repair as necessary 3 Check the hose connecting the LP gas cylinder to ensure it is not damaged Replace as necessary 4 Verify air shutter area is clean 1 Verify all gas connections are tight and leak free 2 Clean burner top inspect for plugged ports corrosion or ...

Page 18: ... NGK 17 1 5 Orifice LP 36 For CB 2424 LPK 36 1 6 Orifice NG 21 For CB 1242 NGK 21 1 7 Orifice LP 43 For CB 1242 and CB 2424 LP 20lb tank CB 20 LP CB 1224 LP LPK 43 1 9 Valve Assembly SRV VA CB 1 11 Piezoelectric Igniter CF Sparker 1 12 Ignition Electrode CB 20 CF 1224 CB 2424 CB 1242 CB Electrode CB 20 CB 1 13 Replacement Fire Glass for CabanaCoast Fire Pit 5lb bag CCB20 Glass 1 14 Grounding wire ...

Page 19: ...oid if the Product or any component has been removed repaired or replaced before CabanaCoast has been afforded a reasonable oppor tunity to inspect the Product This warranty is limited to the replacement or repair of defective components or workmanship and CabanaCoast may fully discharge its obligations under this warranty by repairing or replacing at its discretion the defective compo nents Caban...

Reviews: