D. LP Gas Supply
• The pressure regulator and hose assembly supplied
with LP models must be used. Replacement pressure
regulators and hose assemblies must be those speci-
fied in this manual.
• The LP gas supply cylinder used with LP models must
be constructed and marked in accordance with the
specifications for LP gas cylinders of the U.S. Depart-
ment of Transportation (DOT).
• Cylinders must be stored outdoors in a well ventilated
area out of the reach of children. Disconnected cylin-
ders must have threaded valve plugs tightly installed
and must not be stored in a building, garage or any oth-
er enclosed area.
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION SERVICES, OR MAINTENANCE
CAN CAUSE INJURY OR PROPERTY DAMAGE. REFER TO AND UNDERSTAND THIS MANU-
AL. FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED INSTALLER,
SERVICE AGENCY, LICENSED TECHNICIAN OR THE GAS SUPPLIER.
Gas Setup for Liquid Propane
1.
With burner in place in CabanaCoast® fire pit
table or other installation location and proper
sized orifice inserted in burner neck (see chart on
p.4 for orifice sizing), locate flexible rubber pro-
pane hose and regulator supplied with this burn-
er.
2.
Attach the propane hose to incoming gas fitting
on the gas valve. For CabanaCoast® gas valves
and control panels, this is the lower fitting. Using
two wrenches, one to hold the valve and one to
turn the valve fitting. Tighten securely.
3.
Locate the metal flex-line gas hose and tighten
securely to the top valve fitting following the
method described in step 2.
4.
Using two wrenches, securely tighten the flare
nut on the free end of the metal flex hose to the
orifice on the burner.
5.
For liquid propane installations, the air shut-
ter may be left open as shown at right to pre-
vent sooting.
To adjust air shutter, loosen the
small securing screw and rotate air shutter to
allow more or less airflow. Closing the shutter will
produce a more yellow flame but may soot.
CabnaCoast® fire pit Control panel kit
CHECK ENTIRE SYSTEM FOR LEAKS BEFORE OPERATING
• Storage of this appliance indoors is permissible only if
it has been disconnected from its fuel supply (natural
gas line or LP gas cylinder).
• The LP gas cylinder supply system must be arranged
for vapor withdrawal.
• The LP gas cylinder used must include a collar to pro-
tect the cylinder valve.
• When an LP model is not in use, the LP gas must be
turned off at the supply cylinder.
• The specific size and capacity of the cylinder(s) to be
used: 20 lb. or hard plumbed to propane tank.