Application Examples
Variable Transition Pulse Waveforms
15
The waveform should be that shown in the diagram. The rise and fall times can be
reduced by increasing the main generator frequency and the relationship between rise and
fall time can be altered by changing the symmetry.
Band-Limited Pulses
The edges of these band limited pulses are made up from sine wave segments, starting
from -90 °.
Normally the rise and fall times will be equal, so the main generator symmetry is set to
50 %.
Following on from the example above, set the symmetry and waveform using
SYMMETRY
,
5
,
0
,
%
,
SINE
.
If the trigger parameters have been changed from the above example, re-enter them.
sha0015f.emf
Pulses With Overshoot
Again, the edges and overshoot peaks in this waveform are made up of sine wave
segments. The amount of overshoot depends on the starting phase angle which will be
from -89 ° to about +30 °. The main generator amplitude determines the amplitude of the
peaks;. the amplitude of the flat portions depends on the
PHASE
.
Following on from the previous examples, set the frequency to 20 kHz and open the
trigger menu using the key sequence
FREQ
,
2
,
0
,
kHz
,
EDIT
,
TRIG
.
Move the edit cursor to the
PHASE
field and use the rotary control to adjust the phase
which will vary the amplitude of the flat portion, creating variable overshoot.
sha0016f.emf
15-5
1.888.475.5235
Fluke-Direct
.com
Summary of Contents for DDS Function Generator 271
Page 12: ...271 Users Manual x 1 888 475 5235 info Fluke Direct com Fluke Direct com ...
Page 22: ...271 Users Manual 1 10 1 888 475 5235 info Fluke Direct com Fluke Direct com ...
Page 34: ...271 Users Manual 4 6 1 888 475 5235 info Fluke Direct com Fluke Direct com ...
Page 46: ...271 Users Manual 5 12 1 888 475 5235 info Fluke Direct com Fluke Direct com ...
Page 52: ...271 Users Manual 6 6 1 888 475 5235 info Fluke Direct com Fluke Direct com ...
Page 60: ...271 Users Manual 8 4 1 888 475 5235 info Fluke Direct com Fluke Direct com ...
Page 64: ...271 Users Manual 9 4 1 888 475 5235 info Fluke Direct com Fluke Direct com ...
Page 76: ...271 Users Manual 12 4 1 888 475 5235 info Fluke Direct com Fluke Direct com ...
Page 80: ...271 Users Manual 13 4 1 888 475 5235 info Fluke Direct com Fluke Direct com ...
Page 90: ...271 Users Manual 15 6 1 888 475 5235 info Fluke Direct com Fluke Direct com ...
Page 110: ...271 Users Manual 16 20 1 888 475 5235 info Fluke Direct com Fluke Direct com ...
Page 112: ...271 Users Manual 2 1 888 475 5235 info Fluke Direct com Fluke Direct com ...
Page 132: ...4 1 888 475 5235 info Fluke Direct com Fluke Direct com ...