9 Troubleshooting
Problems
Cause
Solutions
Ref. Paragraph
The main switch is set to "I -
ON", but the machine does
not switch on.
The plug is not inserted in the
outlet.
Insert the plug in the outlet.
5.6.1
The cable is damaged.
Replace the damaged cable.
5.6.1
The outlet is not providing power.
Check the electrical power line.
5.6.1
The machine is on but the
lower rubber roller is not
rotating.
The emergency button is pressed.
Turn the button to release it and
press the reset button.
6.5
The safety reset button has not
been pressed.
Press the safety reset button.
6.3
The safety light curtain beam has
been interrupted.
Remove the cause of the light
curtain interruption and press the
safety reset button.
6.3
Pedal operation has been activated. Deactivate pedal operation.
6.3
The roll on the unwinding
shaft is turning with difficulty.
Excessive brake regulation.
Reduce the braking intensity using
the adjustment knob.
6.6
The liner is too taut and tends
to unwind the roller
positioned on the spindle
shaft.
Excessive clutch regulation.
Reduce the force of the clutch via
the adjustment knob.
6.6
The printed material tends to
create small undulations
during lamination.
Excessive working pressure
between the two rubberised rollers.
Increase the distance between the
rubber rollers via the adjustment
knob.
7.16
GALAXY
USE AND MAINTENANCE MANUAL
EN
MANUAL CODE: 756100330_EN
REVISION: 0
DATE: 07/03/2019
FLEXA S.r.l. - Partial or whole reproduction prohibited without authorisation
79
Summary of Contents for CWT GALAXY
Page 2: ......
Page 93: ......
Page 94: ...FLEXA Sr l reserves the right to make technical changes to this manual without prior notice...