7.14 Roller cooling procedure
It is a good idea to cool the rollers down after processing.
Before activating roller cooling, make sure that there is no material being processing between the rollers and that the protective
liner recovery clutch is not excessive, to prevent that material on the unwinding shaft be rewound.
Perform the following operations:
Press button (A) to deactivate roller heating.
1.
The corresponding LED will switch off.
2.
Leave the rollers in rotation and in close contact for at
least 20 minutes from when heating is deactivated.
3.
Press button (B) to deactivate roller rotation.
4.
Lift the upper roller using the adjustment hand-wheel.
5.
During the cooling operation, the rubber rollers must be in rotation and in contact with one another. A failure to
comply with this rule could cause the heated rubber rollers to become deformed.
GALAXY
USE AND MAINTENANCE MANUAL
EN
MANUAL CODE: 756100330_EN
REVISION: 0
DATE: 07/03/2019
FLEXA S.r.l. - Partial or whole reproduction prohibited without authorisation
49