![Flavor Burst FB 80-08 Manual Download Page 20](http://html1.mh-extra.com/html/flavor-burst/fb-80-08/fb-80-08_manual_2303434020.webp)
19
DAILY OPENING PROCEDURES
NOTE:
YOUR HANDS SHOULD BE CLEANED
AND SANITIZED BEFORE YOU PERFORM
THE FOLLOWING PROCEDURES.
NOTE:
THE FOLLOWING PROCEDURES
REQUIRE APPROVED, SERVICEABLE AND
SANITIZED TOOLS AND BRUSHES.
CONTACT YOUR LOCAL DISTRIBUTOR FOR
RECOMMENDED SUPPLIES.
NOTE:
USE AN APPROVED CLEANER AND
SANITIZER FOR THE FOLLOWING
PROCEDURES. REFER TO
MANUFACTURER’S INSTRUCTIONS FOR
PROPER PREPARATIONS OF THESE
CLEANING AGENTS.
NOTE:
INSPECT ALL WEAR ITEMS AND
REPLACE IF NECESSARY.
Ensure that the Injector System has been
disassembled and cleaned according to the
DAILY CLOSING PROCEDURES. This is
typically performed at the close of the previous
business day.
Sanitizing the Injector System
1. Prepare an approved sanitizer solution
according to manufacturer’s instructions.
2. Place the Gear Box, Suspension Bracket,
Gear Cartridge, and Injector Head in
approved sanitizer solution and soak for 1
minute. (See Figure 8.)
Figure 8
3. Remove each part from the sanitizer
solution. Place the items on a sanitary tray
to air dry. (See Figure 9.)
Figure 9
4. Remove the Manifold cap and set it on a
sanitary tray. Spray the Syrup Line
Manifold opening with approved sanitizer
solution and allow it to sanitize for at least 1
minute. (See Figure 10.)
Figure 10
5. Hang the 9-Tube assembly on the 9-Tube
and Drive Motor Bracket to dry. (See
Figure 11.)
Figure 11
Summary of Contents for FB 80-08
Page 5: ...4 General System Overview Figure 1 ...
Page 7: ...6 26 MIS 3067 OPEN CLOSED BUSHING 1 Strain relief for internal 9 Tube Assembly ...
Page 12: ...11 Syrup Pump and Related Parts Figure 4 ...
Page 14: ...13 Sanitizer Pump and Related Parts Figure 5 ...
Page 16: ...15 Electronic Parts and Connections Figure 6 ...
Page 18: ...17 Spare Parts Kit Figure 7 ...
Page 19: ...18 ...
Page 23: ...22 ...
Page 31: ...30 ...
Page 65: ...64 ...