Installation
Seite/Page 154 - Kaptitel/Chapter 14: Installation
14.7.16
14.4.1 Terminal assignments on the Panda iControl2 controller
14.4.1.1 Terminal assignment of 18-pin connector
Fig. 14.4.1.1-1: Terminal assignment of 18-pin connector
14.4.1.2 Fischer Panda standard bus
Fig. 14.4.1.2-1: Fischer Panda standard bus terminal assignment
14.4.1.3 Fischer Panda CAN bus
Fig. 14.4.1.3-1: Fischer Panda CAN bus terminal assignment
Terminal
IN / OUT
Function
1
--
Actuator (optional)
2
I
Cylinder head temperature
3
IN
Exhaust manifold temperature
4 IN
Winding
temperature
5
IN
Reserve temperature
6
IN
Oil pressure
7
IN
Emergency stop
8
--
GND, ground for all temperature sensors
9
--
GND
10
--
Actuator (optional)
11
--
+5V servo motor (red wire)
12
OUT
PWM servo motor (yellow wire)
13
OUT
Booster (optional, depending on generator type)
14
OUT
Fuel pump
15
OUT
Fuel pump
16
OUT
Electric starter
17
OUT
Electric starter
18
OUT
Electric starter
Terminal
Terminal description
Function
1
UBUS
Bus supply voltage
2
GND
Fischer Panda bus ground, ground connection between Panda iControl2 controller and
Panda iControl2 panel
3
REIZ
Exciter line,
is switched to ground by the panel if the controller is to switch on
4
DATA+
Fischer Panda bus data line A
5
DATA-
Fischer Panda bus data line B
6
UBAT
Battery voltage
Terminal
Terminal description
Function
1
UBUS
Bus supply voltage
2
GND
Fischer Panda bus ground, ground connection between iControl2 controller and Panda
iControl2 panel
3
REIZ
Exciter line, is switched to ground by the panel if the controller is to switch on
4
CAN-L
CAN-Low
5
CAN-H
CAN-High
6
UBAT
Battery voltage