Installation
14.7.16
Kapitel/Chapter 14: Installation - Seite/Page 153
Please note!
Due to the terminals being exposed, the protection class
IP 04 applies to the iControl2 panel.
If properly installed with a seal (e.g. Sikaflex), up to IP66
can be achieved.
14.4 Wiring of the Panda iControl2 controller
Fig. 14.4-1: Wiring of the Panda iControl2 controller
The Panda iControl2 controller is connected to the wire harness with the 18-pin jack. The centre 6-pin jack is
designed for the Fischer Panda standard bus. The Panda iControl2 panel is connected to this jack. The Fischer
Panda CAN bus is connected to the 6-pin jack at the bottom right of the circuit board. The configuration of the
connectors is given in the subsequent tables. Siehe “Terminal assignments on the Panda iControl2 controller” auf
Seite 154.
1. Connecting jack for wire harness, 18-pin
2. Connecting jack, 6-pin, Fischer Panda standard bus
3. Connecting jack, 6-pin, Fischer Panda CAN bus for optional use
4. Connecting bolt for phase L3 (load output to inverter) and input from winding L3
5. Connecting bolt for phase L2 (load output to inverter) and input from winding L2
6. Connecting bolt for winding L1
7. Connecting bolt for phase L1 (load output to inverter)
8. Input for supply v12V
9. Pre-heating output