Installation
14.7.16
Kapitel/Chapter 14: Installation - Seite/Page 151
14.2.1 Panda iControl2 panel with installation housing
Fig. 14.2.1-1: Panda iControl2 panel with panel connecting cable and closed housing
14.2.2 Terminal assignments on the Panda iControl2 panel
The Panda iControl2 panel is connected via a 7-pin Phoenix jack.
Fig. 14.2.2-1: Terminal assignment on the Panda iControl2 panel
Note:
Use only original Fischer Panda connecting cables.
Terminal
Terminal description
Cable colour
Function
1
UBUS
white (WH)
Bus supply voltage
2
GND
brown + shielding (BN)
Fischer Panda bus ground, ground connection
between Panda iController and Panda iControl panel
3
REIZ
green (GN)
Exciter wire, is switched to ground if the controller is to
switch on
4
DATA-A
pink (PK)
Fischer Panda bus data line A
5
DATA-B
Grey (GY)
Fischer Panda bus data line B
6
UBATT
--
Autostart
a
a.
A jumper between terminal 6 and 7 closes the autostart contact.
7
USTART/STOPP
--
Autostart
b
b.
A jumper between terminal 6 and 7 closes the autostart contact.