Installation Instructions
Seite/Page 74 Panda PMS 8.000 NE - 42 NE Manual.R05 - Kapitel/Chapter 5: Installation Instructions
22.3.11
5.6.5.2 Position of the water collector
Important Note!
The ideal position of the water collector would be in center underneath the generator. Only in this position it
is assured that the water level can not change drastically in tilted position by the water collector moving out
of the center line. See the following pictures:
Fig. 5.6.5.2-1: Ideal position of the water collector
In this picture, the water collector is mounted in center under-
neath the generator. When the ship tilts, the position of the
water collector related to the critical point at the exhaust duct
changes only slightly.
Fig. 5.6.5.2-2: Tilted position 15 degrees
Tilted position 15 degrees
The distance from the exhaust elbow to the hydrostatic head
derated to 540 mm.