General operation
22.3.11
Panel Generator Control P6+ RE0703_Kunde_eng.R06.1 - Kapitel/Chapter 11: General operation Seite/Page 203
Attention!:
In the event of starting problems, close the sea water inlet
cock. Panda marine generators only.
Should there be any reason to turn the engine (over) or start the engine i.e.
to bleed the fuel system, the sea water inlet cock must be closed! During the
starting process, the cooling water pump is driven with the motor. The coo-
ling water is discharged to the exhaust outlet and, since the motor has not
run, the exhaust pressure is not high enough to expel the sea water which
has been brought to the exhaust outlet. To avoid filling the exhaust outlet
with water and causing further problems, close the inlet sea water valve.
Once the engine is running, be sure to open the inlet valve!
11.6.2 Stopping the generator
1. Switch off load.
2. Recommendation: With turbo engines and during load more
than highly 70% of the rated output, stabilize generator tempera-
ture at least 5 minutes with load switched off.
At higher ambient temperatures (more than 25°C) the
generator should always run for at least 5 minutes without
load, before it is switched off, regardless of the load.
Fig. 11.6.2-1: Stop
3. Press button „off“ (switch off).
LED for "on“ = off.
Attention!:
Never switch off the battery until the generator has stopped, if
necessary close fuel valve!