General operation
22.3.11
Panel Generator Control P6+ RE0703_Kunde_eng.R06.1 - Kapitel/Chapter 11: General operation Seite/Page 209
The use of these connections for other purposes, other than the master-slave connection of two generator control
panels, is generally forbidden. In individual cases, after consultation and clarifying the technical details, a release for
another use can, if technically possible, be allowed.
11.8.5.2 Terminal X3
Fig. 11.8.5.2-1: Terminal connections terminal X3
Notes:
1.Power rating of the output: max. 0,5A in continuous operation and briefly 1,0A.
2.The supply of all output currents may not exceed (less 0,2A power consumption) the rated current of the safety device of the control panel.
3.The output has a free wheeling diode, which short circuit negative voltages (related to GND).
4.The output has a Z-diode, which prevents an overvoltage (related to GND) into the output.
30
LED-AC-Fault
(Fuel Level)
O
Output for LED AC-Fault on the Slave panel, is switched to GND, if the LED is illuminated
31
LED-T-Win-
ding
O
Output for LED T-Winding on the Slave panel, is switched to GND, if the LED is illuminated
32
DC-Control
O
Output for LED DC-Control-display on the Slave panel. The DC control signal is ground through
1:1.
33
AC-Control
Output for LED AC-Control-display on the Slave panel. The AC control signal is ground through
1:1.
34
VBFS
O
power switched (otherwise like 21, VBF)
Pin-No.
Pin-name
IN / OUT
Description
35
Panel ON
O
With panel (ON/OFF) switched voltage of clamp X2.1 (VBF). (Consider notes 1-4)
36
Error
O
Output is switched on, if a ceitical error is present. (Consider notes 1-4)