![Fischer Panda 45i pms User Manual Download Page 89](http://html1.mh-extra.com/html/fischer-panda/45i-pms/45i-pms_user-manual_2294277089.webp)
Installation Instructions
8.10.14
Kapitel/Chapter 6: Installation Instructions - Seite/Page 89
Fig. 6.10.1-3: externer Feinfilter
External fine filter
At generators with Kubota EA 300 or Farymann engines, the fine filter is
delivered with the generator. This fine filter should be installed in the fuel
feed line next to the generator.
representative picture
6.10.2 Connection of the fuel lines at the tank
Note:
General fuel feed and return line must be connected to the tank at separate
connection points.Lead the return fuel pipe connected to the day tank to the
floor
Connection of the return pipe to the tank
The return pipe connected to the tank must be dropped to the same depth as the suction pipe, if the generator is
mounted higher than the tank, in order to prevent fuel running back into the tank after the motor has been switched
off, which can lead to enormous problems, if the generator is switched off for a long period.
Non-return valve in the suction pipe
A non-return valve must be fitted to the suction pipe, which prevents the fuel flowing back after the generator has
been switched off, if it is not possible to use the return flow pipe as a submerge pipe placed in the tank. The instruc-
tions „Bleeding Air from the Fuel System“ must be read after initial operation or after it has stood still for a long
period, in order to preserve the starter battery.
ATTENTION!
Non-return valve for the fuel return pipe
If the fuel tank should be installed over the level of the genera-
tor (e.g. daily tank), then a non-return valve must be installed
into the fuel return pipe to guarantee that through the return
pipe no fuel is led into the injection pump.
Summary of Contents for 45i pms
Page 3: ...8 10 14 Kapitel Chapter A Seite Page 3...
Page 4: ...Seite Page 4 Kaptitel Chapter A 8 10 14...
Page 12: ...Seite Page 12 Kaptitel Chapter 1 8 10 14...
Page 148: ...Generator Failure Seite Page 148 Kaptitel Chapter 8 Generator Failure 8 10 14...
Page 160: ...Tables Seite Page 160 Kaptitel Chapter 9 Tables 8 10 14...
Page 176: ...Inverter Panda PMGi 45 Seite Page 176 Kaptitel Chapter 10 Inverter Panda PMGi 45 8 10 14...
Page 212: ...Seite Page 212 Kapitel Chapter 6 Annex 8 10 14 Leere Seite Intentionally blank Annex...