Maintenance Instructions
Seite/Page 142 - Kaptitel/Chapter 7: Maintenance Instructions
8.10.14
Fig. 7.23.1-4: Impeller pump
Pull to the impeller with a multigrip pliers of the wave.
Mark the impeller, to make sure that these is used in the correct position at
re-installation.
Representative picture
Fig. 7.23.1-5: Impeller
Check to the impeller for damage and replace it if necessary.
Before the reinsertion into the housing the impeller should have been lubri-
cated with glycerin or with a non-mineral oil based lubricant e.g. silicone
spray.
The impeller is attached to the pump wave (if the old impeller is used, pay
attention to the before attached marking).
Representative picture
Fig. 7.23.1-6: Gasket
Fastening the cover and use a new seal.
Representative picture