![Fischer Panda 45i pms User Manual Download Page 105](http://html1.mh-extra.com/html/fischer-panda/45i-pms/45i-pms_user-manual_2294277105.webp)
Maintenance Instructions
8.10.14
Kapitel/Chapter 7: Maintenance Instructions - Seite/Page 105
7.8
Verifying the starter battery and (if necessary) the battery bank
Check the condition of the battery. Proceed here as prescribed by the battery manufacturer.
If from the battery manufacturer not otherwise mentioned.
7.8.1 Battery
7.8.1.1 Check battery and cable connections
Fig. 7.8.1.1-1: Battery
• Keep battery clean and dry.
• Remove dirty clamps.
• Clean terminal posts (+ and -) and clamps of the battery,
and grease with acid-free and acid-resistant grease.
• When reassembling, ensure that clamps make good con-
tact. Tighten clamp bolts hand-tight.
7.8.1.2 Check electrolyte level
Fig. 7.8.1.2-1: Battery
• Remove sealing caps 1.
• If testers 2 are present:
• Electrolyte level should reach the base of these.
• Without testers:
The electrolyte level should be 10-15 mm above the top of
the plates.
• If necessary, top up with distilled water.
• Screw sealing caps back in.
7.8.1.3 Check electrolyte density
Summary of Contents for 45i pms
Page 3: ...8 10 14 Kapitel Chapter A Seite Page 3...
Page 4: ...Seite Page 4 Kaptitel Chapter A 8 10 14...
Page 12: ...Seite Page 12 Kaptitel Chapter 1 8 10 14...
Page 148: ...Generator Failure Seite Page 148 Kaptitel Chapter 8 Generator Failure 8 10 14...
Page 160: ...Tables Seite Page 160 Kaptitel Chapter 9 Tables 8 10 14...
Page 176: ...Inverter Panda PMGi 45 Seite Page 176 Kaptitel Chapter 10 Inverter Panda PMGi 45 8 10 14...
Page 212: ...Seite Page 212 Kapitel Chapter 6 Annex 8 10 14 Leere Seite Intentionally blank Annex...