Maintenance Instructions
Seite/Page 126 - Kaptitel/Chapter 7: Maintenance Instructions
8.10.14
7.17 Replacing the Glow Plugs
NOTE:Representative procedure
The described procedure is representative for Fischer Panda generators.
The original location of the item must be taken from the generator descrip-
tion of this manual. All replacements and repairs should be done by a trained
person.
ATTENTION!
Ensure that the generator cannot be started up accidentally.
Remove battery main switch.
Fig. 7.17-1: Glow plugs
1. Open the capsule.
01. Glow plugs
Fig. 7.17-2: Glow plugs
Figures similar!
2. Remove the three hex screws using a size 7 mm socket
wrench .
01
01
01
7