FISCHBEIN
®
Co. MODEL PBC-6000™
OPERATOR’S MANUAL
REV. D 2005-03
10
5 INSTALLATION
5.1 RECOMMENDED WORK AREA LAYOUT
5.2 SITE AND SYSTEM PREPARATION
ELECTRICAL POWER HOOKUP
The system is wired at the factory for the voltage specified when ordered. Customers are required
to supply incoming electrical connections. SO 12/4 (12 AWG/4 wire) (4 mm
2
) is recommended.
CAUTION: Be sure machine is connected to building electrical ground
. Follow National
Electrical Code (NEC) and all local electrical codes during installation.
Note:
Electrical
schematics for each unit’s particular voltage option are shipped inside the electrical connection
box on the back of the unit.
For load specifications refer to
TABLE 1 on page 8
.
PNEUMATICS HOOKUP
Connect the air source with a female quick release air coupling (Foster Series 3, #3003 or
equivalent) to the safety shut-off valve, located on the pneumatic control panel (
Illustration 6,
page 14
). Air hose connections must have a minimum 1/2 in. (13 mm) ID. The PBC 6000
requires compressed, clean, dry, non-lubricated air. The supply must be capable of sustaining 90
PSI (6,2 bar) of pressure and a volume flow rate of at least 400 SCFH (11,3 SCMH).
Illustration 5.1 (Top View)
Summary of Contents for PBC-6000
Page 69: ...FISCHBEIN Co MODEL PBC 6000 OPERATOR S MANUAL REV D 2005 03 72 this page left blank...
Page 71: ...FISCHBEIN Co MODEL PBC 6000 OPERATOR S MANUAL REV D 2005 03 75 this page left blank...
Page 73: ...FISCHBEIN Co MODEL PBC 6000 OPERATOR S MANUAL REV D 2005 03 78 this page left blank...
Page 75: ...FISCHBEIN Co MODEL PBC 6000 OPERATOR S MANUAL REV D 2005 03 81 this page left blank...
Page 77: ...FISCHBEIN Co MODEL PBC 6000 OPERATOR S MANUAL REV D 2005 03 84 this page left blank...
Page 79: ...FISCHBEIN Co MODEL PBC 6000 OPERATOR S MANUAL REV D 2005 03 87 this page left blank...
Page 81: ...FISCHBEIN Co MODEL PBC 6000 OPERATOR S MANUAL REV D 2005 03 90 this page left blank...