background image

 

 
 

C-10 Series 

 

Configurable Counting Scales 

 

Operation Manual (Full Version) 

 

 

 
 
 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE OPERATING THIS INSTRUMENT 

 

 

 

 

Specifications subject to change without prior notice 

 

 

 

 

 

V126 January 2021 

Summary of Contents for C-10 Series

Page 1: ...eries Configurable Counting Scales Operation Manual Full Version PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE OPERATING THIS INSTRUMENT Specifications subject to change without prior notice V126 January 2021 ...

Page 2: ...2 ...

Page 3: ...5 1 Power Adaptor 16 5 2 Before Plugging in Power Adaptor to Electricity Grid 16 5 3 Before First Time Use 16 5 4 CR1220 Real Time Clock Backup Battery 16 5 5 Battery Voltage and Battery Operation Application 16 5 6 Battery Lo 16 5 7 Battery Charging Status 16 6 Internal Function Settings 17 6 1 About Internal Function Table 17 6 2 How to Enter Select Internal Function 17 6 3 Key Function during I...

Page 4: ...31 9 9 2 Repetitive multiple tare 31 9 9 3 Preset tare 31 9 10 Auto Power Saving Auto Power off Time 31 9 11 Expiry Date 32 9 12 Print a Customer Product Code Entered 32 9 13 Inputting Numbers Letters Symbols by Keyboard 32 10 Piece Count 32 10 1 Obtain Unit Weight 32 10 1 1 Direct unit weight entry method 32 10 1 2 Sampling method 33 10 1 3 Employ the last unit weight when power on 33 10 1 4 Reca...

Page 5: ...lue Quick PLU 38 11 4 1 Create save preset tare value to quick PLU 38 11 4 2 Recall preset tare value from quick PLU 39 11 4 3 Clear preset tare value from quick PLU 39 11 5 Product Code and Product Description 39 11 5 1 Create save product code and product description to quick PLU 39 11 5 2 Recall product code and product description from quick PLU 39 11 5 3 Clear product code and product descrip...

Page 6: ...bi Memory Management Report 45 14 4 Totalization 45 15 Barcode Scanner 45 15 1 Using Barcode Scanner to Simulate Operation Key Input 45 15 2 Inputting Customer Product Code and Operator Number 45 15 2 Change to Different Input Target 46 15 3 More about Customer Product Code Description 46 16 Commands 46 17 System Message Error Code 47 17 1 System Message Table 47 17 2 Error Code Table 47 18 Daily ...

Page 7: ...es 65 J 1 Get the below ready before Printer Installation 65 J 2 BarDrawer Software Printer Driver Installation 65 J 3 Create Upload Label to Sbarco Printer 66 Appendix K Label Programming Illustration Samples 68 K 1 Label Prompt Command Table 68 K2 Label programming Illustration 70 K 2 1 Label Illustration for LP50 TSC 70 K 2 2 Label Illustration for Sbarco 70 K 3 Sample Labels 70 K 4 Quick Acces...

Page 8: ...stomized Operation Settings PLU Saving Commands 90 T 1 Command Description Table 90 T 2 Parameter Description Table 91 Appendix U Customized Operation Settings PLU Reading Commands 93 U 1 Command Description Table 93 U 2 Parameter Output Description Table 94 ...

Page 9: ...nstrument No warranty service will be provided if the seal or stamp or data plate affixed to this instrument is damaged or removed Always contact your dealer for after sales service 1 3 Warm Up Time a Allow warm up period of not less than 60 seconds before calibration and usage The higher the setup resolution of the scale the longer the warm up period is required In most cases 120 seconds is a saf...

Page 10: ...ange Max or Max1 Subtractive Tare AD Conversion Speed 15 30 60 120 times second Counting Resolution 1 2 million Repeatability Typical 1 5d Safe Weight 1 4d of the Sampling Platform Power Source Rechargeable Battery 6V 4AH External Power Adaptor DC 12V 1A Operation Environment Version L 0 40o C Version M H 10 35o C Non condensed R H 85 Optional External Platform Input Capacity and Readability Free ...

Page 11: ...ntity Quick access to label settings 2 On Off Power instrument on or off Quit without saving and power off 3 QTY Numeric value QTY To introduce the numeric value being displayed on LCD3 as sample quantity QTY Check Start inputting Lo and Hi limit in terms of quantity Enter internal function during power on countdown process 4 PLU Short press Recall operation parameter from Customized Setting PLU T...

Page 12: ...r next internal function number 7 Tare To tare off the weight of a container Nil 8 MR Recall total accumulated results Go to previous parameter or previous internal function number 9 Zero Set weight displayed to zero when unloaded Quit without saving 10 Print M Send print data out and or accumulate current values to memory Enter save and return 11 CE x10 Clear value entered during setting process ...

Page 13: ...ngs 25 Qty Check Indicator Visible when current Hi Lo check function is in term of quantity 26 Weight Check Indicator Visible when current Hi Lo check function is in term of weight 27 Weight Unit Indicator kg kilogram g gram 28 Unit Weight Indicator Visible when unit weight value is displayed on LCD3 29 LCD3 LCD display panel 3 Unit weight and value being edited is displayed here 30 Unit Weight Lo...

Page 14: ...nput External power adaptor DC12V 1A center positive is plugged in here Do not plug in any other power adaptor than the one which comes with this instrument B Comport 0 UART 0 RS232 Refer to below 4 4 for pin assignment C Comport 2 UART 2 RS232 D RS485 and External Input Port Refer to below 4 3 for pin assignment E External Platform Input Load cell cable of P2 is thread through here Refer to below...

Page 15: ...ontact your dealer for support if necessary 2 Remote Sense ve 3 Excitation ve 4 Remote Sense ve 5 Signal ve 6 Signal ve 7 Ground 4 3 RS485 and External Input Port Pin Assignment Table Pin Pin Assignment Notes 1 RS485 A 2 RS485 B 3 No Connection 4 5 6 External Input GND Do not mix share this ground with others 7 External Input 1 8 External Input 2 9 External Input 3 4 4 RS232 Comports Pin Assignmen...

Page 16: ...e Contact your dealer for details and supports 5 5 Battery Voltage and Battery Operation Application Battery voltage is displayed during power on countdown process on LCD1 and by means of internal function F2 Battery voltage below 6 0 is low and is not recommended for any battery operated application which lasts for longer than 60 minutes depends on actual system configuration 5 6 Battery Lo When ...

Page 17: ... on again During countdown process press QTY b If F31 is Set Press PF Set during normal operation status 1 Instrument displays F1 and is now in internal function mode 2 Press PF Set and MR to access the preferred internal function number 3 Quick access to a function number a Press 0 to go to F1 b Press 1 to go to F10 c Press 2 to go to F20 d Press 3 to go to F30 6 3 Key Function during Internal Fu...

Page 18: ...ity division and weight unit Capacity x Division of MAX1 is shown on LCD2 Value displayed Max1 d1 Capacity x Division of W2 if set is shown on LCD3 Value displayed Max2 d2 F4 Date Format Date DD MM YY YY MM DD MM DD YY Press MR or PF Set to change date format and press Print M to confirm Then press Print M to check current date value To change date value press Print M then enter date value and pre...

Page 19: ...F8 Brightness Brightness 01 99 Default 60 Color Ratio 01 99 Default 50 To change setting enter value through numeric keys and press Print M Set brightness bt first then set color ratio Color ratio is used to generate the preferred yellow color When instrument is powered by built in rechargeable battery backlight will be turned to minimum when battery is low or when weight value remains unchanged f...

Page 20: ...ntin All stable weight applied will be tared off Minimum tare load 20d If Contin is set select also delay time 0 0 9 9 second Delay time is the time duration from a stable weight is detected and until it is automatically tare off Delay time value is displayed on LCD3 Enter the preferred delay time value through numeric keys and press Print M to save F13 Repetitive Tare Function Off On If F12 is se...

Page 21: ...M 2 Enter Machine ID number 00 98 and press Print M To clear machine ID number press CE x10 and press Print M to save 3 Enter group number 00 99 and press Print M To clear group number press CE x10 and press Print M to save and return to F18 F19 Manual Entry for Customer Product Code Description P Code Product Code Description C Code Customer Code Description Customer Product code accept both nume...

Page 22: ...Notes If a different operator number than what is running now is entered instrument displays Clear The operator number entered will be carried out on output formats Lab 3 Lab 5 F29 Read Calibration Parameter Counts and Pointer Value C Calibration count shows total times of calibration O Parameter set count shows total times that the important parameters F80 F88 has been altered Press Zero to quit ...

Page 23: ...signing RS485 for report output unless Machine ID set in F18 is blank 3 Press MR or PF Set until the preferred report output port appears on LCD2 and press Print M 4 Instrument displays report content detail setting and parameter on LCD2 and LCD3 respectively At this point report output comport No is set Press Zero to quit to F33 or continue with below to set preferred report content detail parame...

Page 24: ...le Header Footer 7 Press PF Set until the preferred parameter On Off appears on LCD3 and press Print M to save and go to next report content detail parameter setting 8 Repeat above steps 6 and 7 to set all other report content detail until instrument returns to F33 At this point report content detail setting is completed Refer to paragraph 14 for more information F34 Report Output Search Criteria ...

Page 25: ...he preferred output date duration parameter appears on LCD3 and press Print M If Day is selected enter the requested date value and press Print M to output If Month is selected enter the first date of the requested month value e g 17 12 01 for the month of December 2017 and press Print M to output If Period is selected enter the requested starting date value and press Print M and then enter the re...

Page 26: ... order of the internal function number 12 Conduct test runs to determine if the above settings best suit the application requirements If not set again the corresponding parameters Notes a Some of the above internal functions are platform sensitive and it is possible to have different settings for P1 and P2 under the same internal function number b Complete first all settings checking for P1 Then g...

Page 27: ...predefined format CMD Command communication with computer and APP mode Scaner Connect with a barcode scanner UART 0 and UART 2 only Notes If PC or CMD or Barcode Scanner is set refer to paragraph 8 2 for rest of the setting If Auto 1 3 or Manual is set refer to paragraph 8 3 for rest setting 5 Repeat above steps 1 4 for all other UARTs 8 2 Parameters Table for PC Command Scanner Step No Set Item P...

Page 28: ...E for details Lab 3 Database output mode Refer to Appendix F for details Lab 4 Journal output format with gross and net weight of each individual transaction Refer to Appendix G for details Lab 5 Journal output format with time and net weight of each individual transaction Refer to Appendix H for details LP 50 TSC Sbarco Output to LP 50 TSC Sbarco label printer Refer to Appendix I K for details No...

Page 29: ...BT Then set transmission type should be set to CMD 3 Bluetooth Type of internal function F50 For Android set to BT2 0 Then set Bluetooth working type to Andro For iOS set to BT4 0 Then set Bluetooth working type to iOS 4 Then change or take note of the BT device name and pin number 5 Pair your smart device with the built in BT2 0 module before starting the APP 6 Start APP and select the correct Bl...

Page 30: ...ler for support 9 5 1 Select preferred weighing platform by PF Set To enable platform selection through the PF Set set internal function F31 to P F After that by pressing PF Set instrument will shift among P1 only P2 only and both Platform s in operation is indicated by P1 or P2 or PA Indicator 9 5 2 Summing up transaction results of both platforms Transaction results of P1 and P2 can be totalized...

Page 31: ...re This instrument is equipped with multiple tare operation capability Settings Set F13 On to allow multiple tare operation If it is the case instrument will permit multiple tare operation and tare effect can only be cancelled when there is no load on the Platter Set F13 Off to disable multiple tare operation If this is the case tare effect can only be cancelled when container is removed and gross...

Page 32: ...etter entry is in effect Cursor location of current entry is indicated by flashing decimal sign at its right side 10 Piece Count Before count transaction process 1 Remove all loads from weighing platform 2 If zero weight cannot be obtained when unloaded press Zero After Zero is pressed the Zero Indicator will appear 3 If a container is needed place it onto the platform and press Tare manually in c...

Page 33: ...sult and minimize sampling error this instrument is equipped with Auto Unit Weight Enhancement Function This function will be employed when unit weight is determined by sampling method7 Auto Unit Weight Enhancement Function starts when all the below are met a Unit weight is obtained by sampling method as listed on 10 1 2 b 6 pieces quantity added 9999 pieces c 6 pieces quantity added 100 of last t...

Page 34: ...igh LCD1 5 Enter Hi weight check limit the press Print M 6 Instruments returns to normal operation status At this point weight check limit is saved and in effect 10 4 1 2 Employ last check type and limits when power on Last check type and limits before powered off will be employed when powered on again 10 4 1 3 Recall check type and limits from quick PLU For quantity check Refer to paragraph 11 2 ...

Page 35: ...to 1 Auto 2 Auto 3 Manual To enable memory accumulation set Auto Accumulation to On in internal function number F16 To disable memory accumulation set Auto Accumulation to Off in internal function number F16 Refer to step 4 of paragraph 8 3 for setting details 10 5 2 Manual accumulation Press Print M to accumulate the current value to memory 10 5 3 Automatic accumulation12 Automatically memory acc...

Page 36: ... Indicator appears only transaction data of P2 will be accumulated and save MR and memory clearance refers to P2 only When both P1 and P2 indicators appear transaction data of both platforms will be accumulated and save MR and memory clearance refers to both platforms 10 5 6 2 Dual platform accumulation rules When dual platform PA operation is selected transaction data will only be accumulated to ...

Page 37: ...t M 4 Instrument displays Done on LCD3 At this point unit weight is saved and in effect 11 1 2 Recall unit weight from quick PLU Procedures 1 During normal operation status press 0 and press WT 2 Instrument displays Recall on LCD1 3 Press the preferred quick PLU number 0 9 and press Print M 4 Instrument displays Done on LCD3 At this point selected unit weight is recalled and in effect 11 1 3 Clear...

Page 38: ...uick PLU by pressing the quick PLU number 0 9 and press Print M At this point weight check limit is saved and in effect 11 3 2 Recall weight check limit from quick PLU Procedures 1 If more than one weighing platform is used shift to the preferred platform 2 During normal operation status press WT then Check then PLU 3 Instrument displays Recall on LCD1 4 Press the preferred quick PLU number 0 9 an...

Page 39: ...ument displays L code followed by the 3rd 6 digits Enter the last 6 digits of the code here and press Print M to confirm 6 Instrument displays first 6 digits of description content 7 Enter description starting from H then M1 M2 M3 and finally L Press Print M to confirm and end editing after last digit has been input 8 Instrument displays PLU on LCD3 9 Save product code and product description to a...

Page 40: ...here and press Print M to confirm 6 Instrument displays first 6 digits of description content 7 Enter description starting from H then M1 M2 M3 and finally L Press Print M to confirm and end editing after last digit has been input 8 Instrument displays PLU on LCD3 9 Save customer code and customer description to a preferred quick PLU by entering the quick PLU number 01 99 and press Print M 10 Inst...

Page 41: ...tity 9 Check Target weight quantity 10 Auto Tare Type i e Manual or Auto or Continuous 11 Preset Tare Value 12 Date Format 13 Expiry Duration 12 1 Save Current Operation Settings Parameters to Customized Setting PLU Procedures 1 If more than one weighing platform is used shift to the preferred platform 2 Create and make sure that all the above mentioned 12 operation settings and parameters 2 13 ar...

Page 42: ...it Current Customized Setting PLU Effect Procedures 1 During normal operation status press PLU 2 Instrument displays Recall on LCD1 3 Enter 00 and press Print M At this point Customized Setting Indicator disappears and instrument is running according to system setting 13 Data Output Protocols Formats This instrument supports various PC data output protocol and output formats Refer to below paragra...

Page 43: ...n be generated based on data saved in transaction memory and Criteria set forth in F71 supervisor password is needed to access this internal function and Format set forth in F33 and Search criteria and time duration set forth in F34 Notes The Alibi memory is independent to those data obtained through memory accumulation e g manual memory accumulation by pressing Print M key and auto accumulation r...

Page 44: ...ed b Auto 1 All stable weight starts from gross zero or minus is recorded by system c Auto 2 The highest stable weight value of a weighing process is recorded by system when all loads are removed and gross weight returns to zero or minus d Auto 3 The last stable weight value of a weighing process is recorded by system when all loads are removed and gross weight returns to zero or minus e Manual Tr...

Page 45: ...these 2 criteria will be outputted 14 4 Totalization Except date range All is selected instrument will output the totalized data of below result at the end of the output Total number of transactions of the date range Total Net Weight Total Gross Weight Total Piece Count 15 Barcode Scanner To increase working efficiency this instrument supports serial and Bluetooth barcode scanner which utilizes Bl...

Page 46: ...ecute an action c System parameter operation entry setting commands are used to send system parameters and operation entries to this instrument d System parameter reading commands are used to read system parameters e Operation entry reading commands are used to read those operation information entered e g date time product and customer codes current and accumulated operation results f Operation re...

Page 47: ...f and then power on instrument again to reboot Negative Tare value exceeds display range 17 2 Error Code Table Error Code Description Err 1 Time value error Err 2 Date value error Err 3 Exceed manual zero Err 4 Offset out of range unstable during power on Err 5 No load cell detected Err 6 Tare operation error Err 7 Logic error Hi limit set is lower than Lo limit and Hi is not 0 Err 8 Logic error L...

Page 48: ...communicate with Bluetooth module Err 43 Cannot set Bluetooth module Err 44 Report output from RS485 port but Machine ID not blank Err 46 PLU recalled is blank 18 Daily Care Maintenance Clean the instrument with a soft damp cloth If necessary use a mild detergent in water Do not use any harsh abrasive material acetone volatile solvent thinner or alcohol for cleaning Verify the accuracy of this ins...

Page 49: ...s Net NT Net weight GS Gross weight NET Net Weight S Status Code ST for Stable US for unstable R Revered 7 digits weight value including location of decimal point If there is no decimal point then the last character space SP Space SWA Status Word A SWB Status Word B U Weight Unit kg kilogram lb pound g space gram W 7 digits weight value including location of decimal point If there is no decimal po...

Page 50: ...mat Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Data STX SWA SWB SP Field 1 Net Weight Field 2 Tare Weight CR Protocol 3 Output Format Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Data SOH STX SP W W W W W W W SP U U SP SP SP SP CR LF Protocol 4 Output Format Position 1 2 3 4 5 6 7 8 9 Data R R R R R R R P Protocol 5 Output Format Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 ...

Page 51: ...R LF Protocol 7 Output Format Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Data SOH STX SP W W W W W W W SP U U SP SP SP CR LF Protocol 8 Output Format Position 1 2 3 4 5 6 7 8 9 10 Data STX W W W W W W W ETX Protocol 9 Output Format Position 1 2 3 4 5 6 7 8 9 10 11 12 Data STX SP W W W W W U U ETX ...

Page 52: ...is usually used by computer program to separate various data No data separator is inserted between in front or after control commands Separator in front and after a control code C1 C6 will not be surpassed For example STXdata data dataETX Exception of above is when control codes are in between 2 data For example data CR LF data 6 Instrument displays Item Number then followed by the content page No...

Page 53: ... Data 2 ST Stable US Unstable OL Overload nT GS Net Gross Sign 2 NT Net GS Gross Date Date of Output 10 Time Time of Output 8 Net Net Weight 8 Numeric value only without weight unit Tare Tare Weight 8 Gross Gross Weight 8 Unit Weight Unit 2 kg Kilogram space g gram H ref Hi Limit 8 8 digital including decimal if any L ref Lo Limit 8 8 digital including decimal if any Ck res Comparison Result 2 Lo ...

Page 54: ...transaction 8 Blank none ACC Total Accumulated Weight Transaction Data 8 Blank none unit Wt Unit weight 8 8 digital including decimal if any in terms of gram Qty Number of pieces 8 8 digital t _ Qty Total Accumulated Pieces 8 8 digital P F Platform 2 P1 Built in platform P2 External platform PA P1 P2 t _GS Accumulated Gross Weight 8 8 digital including decimal t _Tare Accumulated Tare Weight 8 Exp...

Page 55: ...10 00kg 4999 2 00000g 45001 kg Accept 2018 8 19 11 54 58 8 PA 20 00kg 2 64kg 22 64kg 110 00kg 10000 2 00000g 55001 kg Below 2018 8 19 12 10 37 10 PA 20 00kg 2 64kg 22 64kg 130 00kg 10000 2 00000g 65001 pcs Accept Notes Date Date of Output Time Time of Output Seq Accumulate Sequence No Platform o P1 built in platform P2 external platform PA P1 P2 Net Net Result Tare Tare Weight Gross Gross Weight T...

Page 56: ... Customer Code Line for Customer Description Customer Code Description Pcode Product Code Product Code Line for Product Description Product Code Description Net 10 00kg Net Weight Total_WT 120 00kg Total Accumulated Net Weight QTY 4999pcs Quantity WT 2 00000g Unit Weight Total_QTY 59990pcs Total Accumulated Quantity One Blank Line is inserted here High 20 00kg Hi Limit Low 10 00kg Lo Limit Result ...

Page 57: ...t GroSS Gross weight unit Wt Unit weight Qty Number of pieces HrEF Hi limit LrEF Lo limit ChrES Comparison result trAnS Transaction sequent number if this transaction is accumulated to memory ACC Total accumulated weight when accumulation function is in effect SiGn Signature PCode Product Code P Desc Product Description Id Machine ID GrouP Machine group number oPCodE Operator number CCode Customer...

Page 58: ...o paragraph E 1 for details stored 4 Press Print M to confirm or select other variant or command by press PF Set or MR Press Print M to confirm and save 5 This instrument displays Line 2 and the last variant or command stored 6 Repeat steps 4 and 5 for other lines 7 To finish editing select command End and press Print M to confirm 8 This instrument returns to and displays the current internal func...

Page 59: ...2 No of Accumulated Transaction Data 3 Platform Number Data 4 Machine ID Data 5 Machine Group Number Data 6 Date of Output Data 7 Time of Output Data 8 Customer Code Data 9 Product Code Data 10 Gross Weight Data 11 Tare Weight Data 12 Net Weight Data 13 Accumulated Weight Data 14 Weight Unit Data 15 Quantity Data 16 Unit Weight Data 17 Weight Unit of Unit weight Data 18 Lo limit Data 19 Hi limit D...

Page 60: ...d Pcode Product Code Product Code if entered Opr 8888 Operator number if entered Mac 11 Machine ID if entered MacGp 22 Machine Group Number if entered Date 2018 08 19 Date of 1st output Time 13 44 00 Time of 1st Output Seq QTY Net Accumulation No platform No quantity and net weight 0001 P1 4999 10 00kg 0002 P2 5000 10 00kg 0005 PA 10000 20 00kg 0005 PA Total accumulation No and platform No of last...

Page 61: ...de if entered Pcode Product Code Product Code if entered Opr 8888 Operator number if entered Mac 11 Machine ID if entered MacGp 22 Machine Group Number if entered Date 2018 08 19 Date of 1st output Seq Time QTY 0002 PA 14 09 07 10000 Accumulation No platform No time and quantity 0004 PA 14 09 15 10000 0003 P1 14 09 25 4999 0003 P2 14 09 29 5001 0003 P2 Total 15003 Total accumulation No platform No...

Page 62: ...propriate cable and then turn on the printer 2 If the printer supports Plug and Play and you have connected it using a USB or Parallel cable then the Windows Add Hardware Wizard will detect the printer and display a dialog that allows you to install a driver Click Cancel and do not install the driver using this wizard 3 Run the Driver Wizard utility from the Installation Directory where the driver...

Page 63: ...el software dealer for more details if in doubt 1 Set the label printer as the default printer of your computer 2 Create the foundation of a label by Bartender All information to be obtained from instrument should be added afterward 3 Once the label foundation has been completed a click on File and b select Export Printer Code Template 4 On Print System a select TSC KP 100 200 Flash and b select t...

Page 64: ...3 enter the appropriate command on the Prompt Box refer to paragraph K 1 for command detail 14 Select Auto on the Source box under Template Field 15 Repeat point 11 to 12 for all other data sources 16 Click OK 17 Click Export In case of Verification Messages appear select one of method on the dialogue box to fix and click Continue ...

Page 65: ...Drawer software is installation is done 3 Run BarDrawer software 4 Click Install Driver under Tools figure 1 below Then install printer driver according to the wizard 5 After printer driver installation click Printer Utility under Tools figure 2 below 6 Click Load from Printer figure 3 below 7 Check FW version If FW version 3 0 05 date 2020 12 18 or newer printer installation is done If FW version...

Page 66: ...t Single Variable c On Format section enter value of Maximum number of characters Refer to K 1 Suggested Length column for suggested value d On Input Data section select After send instructions Hex Then enter the Prompt Command listed on K 1 e Always select 0D 0A for Newline symbol Hex box f Click OK to save above settings for this variable g Repeat above a f for all other variables 6 Once the lab...

Page 67: ...67 7 On Save Form page a make sure that the Form name is correct then b Click Save 8 On Select Store Media page a select Printer then b select Printer s Flash ROM then c click OK ...

Page 68: ...6 OPER Operator No 4 64 MCID Machine ID 4 65 MCGP Machine Group 2 5A CCDE Customer Code 18 43 CCDD Customer Code Description 30 62 PCDE Product Code 18 44 PCDD Product Code Description 30 53 CHKL Low Limit 11 73 chkl6 Low Limit in 6 digit integer 6 52 CHKH High Limit 11 72 chkh6 High Limit in 6 digit integer 6 54 CHKR Check Result 11 51 CWGS Current Gross Weight 10 71 cwgs6 Current Gross Weight in...

Page 69: ...6D aseq6 Accumulation Sequence No in 6 digit integer 6 47 AWGS Accumulated Gross Weight 11 67 awgs6 Accumulated Gross Weight in 6 digit integer 6 4A AWTA Accumulated Tare Weight 11 6A awta6 Accumulated Tare Weight in 6 digit integer 6 4E AWNT Accumulated Net Weight 11 6E awnt6 Accumulated Net Weight in 6 digit integer 6 63 AQTY Accumulated Quantity 11 69 aqty6 Accumulated Quantity in 6 digit integ...

Page 70: ...1 Label Illustration for LP50 TSC K 2 2 Label Illustration for Sbarco K 3 Sample Labels Label files of the above samples size 50 x 80mm with prompt commands are available for download at https www fi measurement com resource driversnsoftwares ...

Page 71: ...int in label format group 2 Enter the preferred file number through numeric then press Print M to confirm 5 At this point label settings are completed K 5 Repetitive Printout This instrument supports repetitive output under Manual Print Mode Press Print M for additional output copies Conditions and criteria as below When Auto Accumulation is set to On Repetitive print is only possible when the act...

Page 72: ...lowed by c Letter shown on below illustration diagram keyboard commands are case sensitive followed by d End String number sign Hex code 23 Example to send manual Zero key command to instrument enter KBA Notes For RS485 communication add xx before start string xx machine ID number set in F18 Keyboard Command Illustration Diagram ...

Page 73: ...communication add xx before start string xx machine ID number set in F18 M 1 Command Description Table System Related Command Definition Command Format Start String Command Code End String System Reboot EX F000 All Segment Check EX F002 System F7 F34 Initialization EX F006 Reset WIFI Module to Default Setting EX F048 Reset Bluetooth Module BT 2 0 only EX F053 Reload Factory Settings to BT Module B...

Page 74: ... memory EX RPTM d1 d2 d3 d4 Output data of specific period in Alibi memory EX RPTP d1 d2 d3 d4 d5 d 6 Search Criteria d1 Data starting date 6 digit according F4 setting d2 Data ending date 6 digit according F4 setting d3 Operator number 0000 9999 Blank all d4 C Code 1 18 digit Customer Code Blank all d5 P Code 1 18 digit Product Code Blank all d6 Check Result Lo Below OK Accept Hi Above NG Lo or H...

Page 75: ...le Command Definition Command Format Parameter Description Start String Command Code Note A Parameter End String Set Date Format Value and Output ST F004 d1 d2 d3 d1 Date Format 0 DD MM YY 1 YY MM DD 2 MM DD YY d2 8 digit date value as per above setting AA BB CC d3 Date Output Format 0 Normal Format 1 Week Format Set Time ST F005 d1 8 digit time value HH MM SS Set Auto Power Off ST F007 d1 0 Off 1...

Page 76: ...tion on Negative Value ST F015 d1 d2 d1 Check Buzzer 0 Off 1 IN 2 Out 3 Hi 4 Lo d2 Action on Negative Value 0 Off 1 On Set Keyboard Lock ST F020 d1 0 Off 1 On Set Near Zero Value S1 or S2 F026 d1 Maximum 8 digits including decimal if any Set Ask for Operator Number when Power On ST F028 d1 0 No 1 Yes Set Allow Letters and Symbols for Customer Product Code Manual Entry ST F030 d1 0 No 1 Yes Set PF ...

Page 77: ...t Maximum 6 digit plus decimal if any Set Quantity Check Limits S1 or S2 CHKQ d1 d2 d1 Lo limit Maximum 6 digit Decimal not accepted Blank nothing d2 Hi limit Maximum 6 digit Decimal not accepted Blank nothing Set Pre set Tare Value Note B S1 or S2 PSTA d1 Maximum 6 digit plus decimal if any Set WT ST AVGW d1 Maximum 6 digit plus decimal if any Blank 0 Set Expiry Duration ST EXPY d1 4 digits 0000 ...

Page 78: ...le Command Definition Command Format Parameter Output Parameter Description Start Strin g Command Code End String Read Internal AD value R1 or R2 F001 d1 8 digits AD value Read Capacity Division Default Weight Unit R1 or R2 F003 d1 d2 d1 Capacity x Division of MAX1 d2 Capacity x Division of MAX2 if set Read Date Format Value and Output Settings RD F004 d1 d2 d3 d1 Date Format 0 DD MM YY 1 YY MM DD...

Page 79: ...030 060 120 Read Auto Tare Function RD F012 d1 M Off A Auto 00 99 Continuous tare in term of 1 10 second Read Repetitive Tare Function RD F013 d1 0 Off 1 On Read Buzzer RD F014 d1 d2 d3 d1 Keyboard Buzzer 0 Off 1 On d2 System Buzzer 0 Off 1 On d3 Non Resettable Memory Buzzer 0 Off 1 On Read Result Buzzer Action on Negative Value RD F015 d1 d2 d1 Check Buzzer 0 Off 1 IN 2 Out 3 Hi 4 Lo d2 System Bu...

Page 80: ...Code Manual Entry RD F030 d1 0 No 1 Yes Read PF Set Key Assignment RD F031 d1 0 Set 1 Platform Read External Input Assignment RD F032 d1 d2 d3 d1 Int 1 0 5 d2 Int 2 0 5 d3 Int 3 0 5 0 Zero 1 Tare 2 Mode 3 Print M 4 MR 5 Clear Read Report Output Comport RD F033 d1 0 UART 0 1 UART 1 2 UART 2 3 UART 3 Read Unit weight before Power Off RD F035 d1 0 Off 1 On Note C R1 command to read parameter for P1 R...

Page 81: ...Start String Command Code End String Read Customer Code RD CCDE d1 1 18 digit Customer Code Blank nothing Read Customer Code Description RD CCDD d1 1 24 Customer Code Adscription Blank nothing Read Product Code RD PCDE d1 1 18 digit Product Code Blank nothing Read Product Code Description RD PCDD d1 1 24 Product Code Description Blank nothing Read Machine ID RD MCID d1 2 digit Machine ID Number Bl...

Page 82: ...Date Value RD DATE d1 8 digit date value Read Expiry Duration RD F036 d1 0 9999 Day Read Time Value RD TIME d1 8 digit time value Read Week Value RD WEEK d1 6 digit time value Read Expiry Date RD EXPY d1 8 digits Format as per F4 setting Read WT in 6 digit format and without decimal RD avgw6 d1 6 digits without decimal ...

Page 83: ... Weight R0 or R1 or R2 or RA CWTA d1 8 digits including decimal Read Current Gross Weight R0 or R1 or R2 or RA CWGS d1 8 digits including decimal if any Read Current Net Weight R0 or R1 or R2 or RA CWNT d1 8 digits including decimal if any Read Weight Unit of Current Net Tare and Gross Weight R0 or R1 or R2 or RA CWUN d1 8 digits including decimal if any Read Qty Value R0 or R1 or R2 or RA CQTY d1...

Page 84: ... format and without decimal R0 or R1 or R2 or RA cwta6 d1 6 digits without decimal Read Current Gross Weight in 6 digit format and without decimal R0 or R1 or R2 or RA cwgs6 d1 6 digits without decimal Read Current Net Weight in 6 digit format and without decimal R0 or R1 or R2 or RA cwnt6 d1 6 digits without decimal Read Qty Value in 6 digit format and without decimal R0 or R1 or R2 or RA cqty6 d...

Page 85: ...git without decimal Read Accumulated Qty Value in 6 digit format and without decimal R0 or R1 or R2 or RA aqty6 d1 6 digit without decimal Read Accumulation sequence No R0 or R1 or R2 or RA aseq6 d1 6 digit without decimal Note D R0 command to read entries and result of current platform in used R1 command to read entries and result of P1 R2 command to read entries and result of P2 RA to read the t...

Page 86: ...mmand Definition Command Format Parameter Description Start String Command Code Note E Parameter End String Save Preset Tare to Quick PLU S1 S2 QP PSTA d1 d2 d1 Quick PLU number 0 9 d2 Maximum 6 digits plus decimal Save Unit Weight in term of g to Quick PLU ST QP AVGW d1 d2 d1 Quick PLU number 0 9 d2 Maximum 6 digits plus decimal Save Check WT Limits to Quick PLU ST S1 S2 QP CHKW d1 d2 d3 d1 Quick...

Page 87: ...ristics Asterisk number sign and semi colon not accepted Blank Nothing Save Product Code and Description to Quick PLU ST QP PCDE d1 d2 d3 d1 Product Code Maximum 18 characteristics Asterisk number sign and semi colon not accepted Blank Nothing d2 Product description Maximum 30 characteristics Asterisk number sign and semi colon not accepted Blank Nothing Note E S1 command to set parameter to Quick...

Page 88: ... Read Preset Tare from Quick PLU R1 R2 QP PSTA 0 9 or A 0 9 PLU number A all d1 Maximum 8 digits plus decimal Read Unit Weight in term of g from Quick PLU RD QP AVGW d1 Maximum 8 digits plus decimal Read Check WT Limits from Quick PLU RD R1 R2 QP CHKW d1 d2 d1 Low check limit d2 Hi check limit Read Check QTY Limits from Quick PLU RD R1 R2 QP CHKQ d1 d2 d1 Low check limit d2 Hi check limit Read Cus...

Page 89: ...d instrument sends content by Quick PLU numeric sequence Note F R1 command to read content from Quick PLU of P1 R2 command to read content from Quick PLU of P2 RD command to read content from Quick PLU which is common for both P1 and P2 ...

Page 90: ...ers listed on below table Always insert semi colon in front of each parameter followed by d End String number sign Hex code 23 Notes For RS485 communication add xx before start string xx machine ID number set in F18 T 1 Command Description Table Start String Command Code Note G Parameter End String S1 or S2 or SA LP d1 d2 d3 d4 d5 d6 d7 d8 d9 d10 d11 d12 d13 Note G S1 command to set parameter for ...

Page 91: ...s Asterisk number sign and semi colon not accepted Blank Nothing d6 Unit Weight In term of g for metric version In term of 1 1000 lb for lb version Maximum 6 digit plus decimal Blank 0 d7 Low Check limit When Check Target is W Maximum 6 digit plus decimal Blank 0 When Check Target is Q Maximum 6 digit Blank 0 d8 Hi Check limit When Check Target is W Maximum 6 digit plus decimal Blank 0 When Check ...

Page 92: ...arameter Description Parameter Blank 0 If Platform is PA enter zero value here d12 Date Format 0 Normal 1 Week d13 Expiry Duration Maximum 4 digits 0 9999 0 or blank F4 value 1 9999 No of day plus F4 value ...

Page 93: ...de 23 Notes For RS485 communication add xx before start string xx machine ID number set in F18 U 1 Command Description Table Start String Command Code Note H Parameter End String Parameter Output R1 or R2 or RA LP 01 99 or A 01 99 PLU number A all d1 d2 d3 d14 Remark If parameter A is entered instrument sends content of quick from PLU 01 to PLU 99 in numeric sequent Note H R1 command to read PLU c...

Page 94: ...scription Maximum 30 characteristics and will not be accepted Blank Nothing d7 Unit Weight in term of g Maximum 8 digits including decimal Blank Nothing d8 Low Check limit Maximum 8 digits including decimal Blank Nothing d9 Hi Check limit Maximum 8 digits including decimal Blank Nothing d10 Check Target W Weight Q PCS d11 Auto Tare Type 0 Manual 1 Auto Tare 2 Continuous Tare d12 Preset Tare Value ...

Page 95: ...Fidelity Measurement Co Ltd www fi measurement com e mail info fi measurement com ...