2. MPA pressure sensor
2−8
Festo P.BE−MPA−ELECTRONIC−EN en 0804NH
Module parameter: Measured value smoothing
Handheld
Function no.
4828 + m * 64 +
8
m = module number of the MPA pressure sensor (1 ... 47)
Description
Sets the level of smoothing of measured values for limit value monitoring. This
can suppress possible spurious values.
Bit
Bits 1, 0
[Filter]
Values
Bit 1 0 Setting:
0 0 No measured value smoothing (default setting)
0 1 Smoothing over 2 values
1 0 Smoothing over 4 values
1 1 Smoothing over 8 values
Tab.2/7: Setting the measured value smoothing