![Festo VMPA-FB-PS Series Manual Download Page 43](http://html.mh-extra.com/html/festo/vmpa-fb-ps-series/vmpa-fb-ps-series_manual_2282602043.webp)
1. MPA pneumatic modules
1−29
Festo P.BE−MPA−ELECTRONIC−EN en 0804NH
Note
The fault Load voltage for valves" is registered for the
complete module as module fault with channel number
0...7 (or 0...3).
Note
In Tab.1/14 the grey−marked fault messages of the red
LED there appears orange when the message is displayed
together with the yellow status LED (applies only to MPA1
pneumatics).
Check by means of the fault number to ascertain which
fault has occurred (diagnostic message to the Fieldbus
or with the Handheld).
1.5.5
Fault treatment and parameterising
Depending on the module parameterising, the faults are sent
to the bus node, where they can be evaluated according to
the Fieldbus protocol used.
Condition Counter of the electronic modules type
VMPA...−
D2
...
With the Condition Counter you can have a message dis
played indicating when a valve has reached a parameterised
limit value of switching cycles:
Use Condition Monitoring
1. Set the counter (Condition Counter) to 0. In order to do
this, you must use the Handheld CPX−MMI (see below)
or set the limit value to 0. The counter will then be reset
as well.
2. With the module parameter (see Tab.1/11) set a limit
value for the desired channel (valve coil). The Condition
Monitoring will then be activated.
Summary of Contents for VMPA-FB-PS Series
Page 2: ......
Page 49: ...MPA pressure sensor 2 1 Festo P BE MPA ELECTRONIC EN en 0804NH Chapter 2 Type VMPA FB PS ...
Page 83: ...Technical appendix A 1 Festo P BE MPA ELECTRONIC EN en 0804NH Appendix A ...
Page 90: ...A Technical appendix A 8 Festo P BE MPA ELECTRONIC EN en 0804NH ...
Page 91: ...Index B 1 Festo P BE MPA ELECTRONIC EN en 0804NH Appendix B ...
Page 92: ...B Index B 2 Festo P BE MPA ELECTRONIC EN en 0804NH ...
Page 96: ...B Index B 6 Festo P BE MPA ELECTRONIC EN en 0804NH ...