1. MPA pneumatic modules
1−18
Festo P.BE−MPA−ELECTRONIC−EN en 0804NH
Module parameter: Idle mode channel x
Function no.
Access to these module parameters is made via protocol−specific functions (see
the bus node description).
Description
Only relevant for certain Fieldbus protocols.
Idle mode channel x: Hold last state
Idle state (presetting)
Idle state channel x: Set output
Reset output (presetting)
Note
With the aid of the so−called Idle mode parameterising, you can determine the
signal status which the outputs are to assume when switching is made to the Idle
state (see also CPX system manual).
This parameter is not available with all Fieldbus protocols.
Tab.1/7: Idle mode channel x (channel−specific)
Module parameter: Force channel x
Function no.
Access to these module parameters is made via protocol−specific functions (see
the bus node description).
Description
Force mode of outputs channel x: blocked (presetting)
Force state
Force state of outputs channel x: Set signal
Reset signal (presetting)
Note
The Force function enables the manipulation of signal states detached from
actual operating states (see also CPX system manual).
Tab.1/8: Force channel x (channel−specific)
Summary of Contents for VMPA-FB-PS Series
Page 2: ......
Page 49: ...MPA pressure sensor 2 1 Festo P BE MPA ELECTRONIC EN en 0804NH Chapter 2 Type VMPA FB PS ...
Page 83: ...Technical appendix A 1 Festo P BE MPA ELECTRONIC EN en 0804NH Appendix A ...
Page 90: ...A Technical appendix A 8 Festo P BE MPA ELECTRONIC EN en 0804NH ...
Page 91: ...Index B 1 Festo P BE MPA ELECTRONIC EN en 0804NH Appendix B ...
Page 92: ...B Index B 2 Festo P BE MPA ELECTRONIC EN en 0804NH ...
Page 96: ...B Index B 6 Festo P BE MPA ELECTRONIC EN en 0804NH ...