![Festo VMPA-FB-PS Series Manual Download Page 53](http://html.mh-extra.com/html/festo/vmpa-fb-ps-series/vmpa-fb-ps-series_manual_2282602053.webp)
2. MPA pressure sensor
2−5
Festo P.BE−MPA−ELECTRONIC−EN en 0804NH
2.1.4
Parameterising the MPA pressure sensor
The following table provides an overview of the MPA pressure
sensor parameters. Sections Tab.2/3 to Tab.2/9 pro vide
detailed information.
Function number
1)
Parameters of the MPA pressure sensor module
4828 + m * 64 +
0
Monitoring parameterisation faults
4828 + m * 64 +
6
Unit for pressure specifications (limit values and current pressure
value)
Delay for pressure diagnosis
4828 + m * 64 +
7
Activate and set limit value monitoring
4828 + m * 64 +
8
Measured value smoothing
4828 + m * 64 +
9
4828 + m * 64 +
10
Lower limit value Low Byte
Lower limit value High Byte
4828 + m * 64 +
11
4828 + m * 64 +
12
Upper limit value Low Byte
Upper limit value High Byte
4828 + m * 64 +
13
4828 + m * 64 +
14
Hysteresis Low Byte
Hysteresis High Byte
1)
m = Module number of the MPA pressure sensor (1 ... 47)
Tab.2/2: Overview of the parameters of the MPA pressure sensor
Summary of Contents for VMPA-FB-PS Series
Page 2: ......
Page 49: ...MPA pressure sensor 2 1 Festo P BE MPA ELECTRONIC EN en 0804NH Chapter 2 Type VMPA FB PS ...
Page 83: ...Technical appendix A 1 Festo P BE MPA ELECTRONIC EN en 0804NH Appendix A ...
Page 90: ...A Technical appendix A 8 Festo P BE MPA ELECTRONIC EN en 0804NH ...
Page 91: ...Index B 1 Festo P BE MPA ELECTRONIC EN en 0804NH Appendix B ...
Page 92: ...B Index B 2 Festo P BE MPA ELECTRONIC EN en 0804NH ...
Page 96: ...B Index B 6 Festo P BE MPA ELECTRONIC EN en 0804NH ...