1. MPA pneumatic modules
1−15
Festo P.BE−MPA−ELECTRONIC−EN en 0804NH
Address assignment within the pneumatic modules
An MPA1 pneumatic module always occupies 8 output
addresses; an MPA2 pneumatic module always occupies
4 output addresses.
Each valve location occupies 2 addresses, irrespective of
whether a valve plate or blanking plate is fitted.
The following assignment applies:
solenoid coil 14 occupies the lower−value address,
solenoid coil 12 occupies the higher−value address.
1
2
5
3
4
7
6
A
x+2
A
x+4
A
x+6
Ox+1
Ox+3
A
x+5
A
x+7
Ay+1
Ay+0
Ay+3
Ay+2
12141214
14
12
14
12
1
4
A
x+0
12
14
5
3
4
3
4
1
MPA1 pneumatic module
2
MPA2 pneumatic module
3
Addresses of coil 14 (channel 0, 2, 4, 6)
4
Addresses of coil 12 (channel 1, 3, 5, 7)
5
Valve plates with two solenoid coils
6
Valve plates with one solenoid coil
(addresses Ax+5 unused)
7
Blanking plate
Fig.1/6:
Example: Address assignment of MPA pneumatic modules (viewed from above)