3. Proportional pressure regulator
3−10
Festo P.BE−MPA−ELECTRONIC−EN en 0804NH
Module parameter: Valve solenoid condition counter
Handheld
Function no.
4828 + m * 64 +
8...11
Condition Counter limit value
| 11 | 10 | 9 | 8 |
m = module number (1 ... 47)
High−Byte Low−Byte
Description
A limit value for a counter (Condition Counter) can be set for the valve coil. A
message is displayed if the limit value is exceeded. An activated Condition
Counter causes the following. The message is:
displayed via the fault LEDs
sent to the CPX Fieldbus node
Bytes
Bit 0 ... 7: High byte or low byte of the limit value
(32 bits value hexadecimal)
[Max. condition
counter]
Values
FFFFFFFF
h
: Condition Counter activated but limit value
inactive (presetting)
2DC6C0
h
: (example) Condition Counter activated and
limit value 3,000,000
d
set.
0:
Condition Counter inactive (counter and
diagnostic message deactivated, counter
reset)
[4294967295
d
]
corresponds to FFFFFFFF
h
[value < FFFFFFFF
h
]
[0]
Tab.3/7: Parameterising Condition counter