1.      Summary  of  components

1−18

Festo    P.BE−CPASC−EN    en  0412b

1.2.4

Connecting  and  operating  elements  of  the  CPA−SC  valve  terminal

The  following  pneumatic  connecting  and  operating  elements
can  be  found  on  the  CPA−SC  valve  terminal:

1

3

4

Valve  terminal  with  sub−base  valves

Valve  terminal  with  semi−inline  valves

2

1

2

3

4

1

Manual  override  covers  (optional)

2

Manual  override  (turning/locking  or  non−locking,  depending  on  pilot  solenoid)

3

Work  connections  (2,  4),  on  the  sub−base  (per  valve  location)  or  on  the  valve

4

Supply  air  connections  (1,  12/14),  exhaust  connections  (3,  5,  82/84)  and
pressure  compensation  connection  (L)  on  the  left−hand  and  right−hand  sides  of
the  sub−base

Fig.1/1:

CPA−SC  valve  terminal:  Pneumatic  connecting  and  operating  elements

Summary of Contents for Smart cubic CPA-SC Series

Page 1: ...Pneumatics manual CPA SC valve terminal CPA SC individual location base block Type CPA SC Manual 530 933 en 0412b 690 375 Compact performance Smart cubic...

Page 2: ......

Page 3: ...ny 2004 Internet http www festo com E Mail service_international festo com The reproduction distribution and utilization of this docu ment as well as the communicaton of its contents to others without...

Page 4: ...Contents and general instructions II Festo P BE CPASC EN en 0412b...

Page 5: ...dent code of the pneumatic components 1 17 1 2 4 Connecting and operating elements of the CPA SC valve terminal 1 18 1 2 5 Connecting and operating elements of the CPA SC individual valve 1 23 2 Fitti...

Page 6: ...l instructions 4 4 4 1 1 Before commissioning 4 4 4 1 2 Pressure build up of the complete supply 4 4 4 2 Manual override 4 7 4 3 Testing the valves and the valve actuator combination 4 9 4 4 LED displ...

Page 7: ...nstallations in orignal condition without any modifications by the user Only the conversions or modifications described in the documentation supplied with the product are permitted in faultless techni...

Page 8: ...exclusively with the pneumatic components and refers to the valve terminal or individual location base block variants listed in the following tables Valve terminals Electrical variants Pneumatic vari...

Page 9: ...ype CPPSC Multipin connection with Sub D socket MP connection Information on electric components See information supplied with the product Multipin connection with plug strip for ribbon cable FL conne...

Page 10: ...s Sub base valves type CPASC Semi inline valves type CPPSC Plug in connection PI connection Information on the electric components in this manual Horizontalconnector HC connection Information on the e...

Page 11: ...ype CPPSC Plug in connection PI connection Information on electric electronic components in thismanual Horizontalconnector HC connection Information on electric electronic components in thismanual Tab...

Page 12: ...en the following danger warnings Warning This means that failure to observe this instruction may result in serious personal injury or damage to property Caution This means that failure to observe this...

Page 13: ...s tips and references to other sources of information Accessories Information on necessary or sensible accessories for the Festo product Environment Information on environment friendly use of Festo pr...

Page 14: ...alve terminal type 82 with HC PI FL or MP connection DI connection CPA SC valve terminal variant field bus direct DeviceNet FL connection CPA SC valve terminal variant with 26 pin multipin plug strip...

Page 15: ...are intended for fitting on PRS base blocks see base blocks Sub base valve Valve plate variant without work connections 2 4 These may only be fitted onto sub bases see base blocks Tubing Connecting t...

Page 16: ...Contents and general instructions XIV Festo P BE CPASC EN en 0412b...

Page 17: ...Summary of components 1 1 Festo P BE CPASC EN en 0412b Chapter 1...

Page 18: ...rview of variants 1 5 1 2 Description of components 1 9 1 2 1 CPA SC valve terminal 1 10 1 2 2 CPA SC individual location base block 1 16 1 2 3 Ident code of the pneumatic components 1 17 1 2 4 Connec...

Page 19: ...f the CPA SC valve terminal connection variants and components on the valve terminal the maximum number of valve locations the identification code of the pneumatic components the connecting display an...

Page 20: ...y incor porate the CPA SC in your machine or system Due to their compact design the CPA SC valve terminals can be fitted close to the actuators to be controlled This enables short compressed air tubin...

Page 21: ...or sub base valves have work connections 2 4 Base blocks for semi inline valves have no work connections as these are situated on the semi inlinevalves Semi inline valves can also be fitted onto base...

Page 22: ...location base block 1 Field bus direct connection DI connection Multipin connection sub D MP connection Plug in connection PI connection Multipin connection with plug strip for flat cable FL connectio...

Page 23: ...tions marked with 1 All other valve locations can be fitted as desired Remark on table No VP number of valve locations No VP Valve location VP 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 2...

Page 24: ...ion is made via the 25 pin sub D multipin plug MP connection or the 26 pin multipin plug strip for flat cables FL connection as per DIN EN 60603 13 Remark on table No VP number of valve locations No V...

Page 25: ...olenoid coils can be controlled CPA SC individual location base block CPA SC with HC connection With this individual location base block electrical connection is made via the valve solenoid coils dire...

Page 26: ...ns Base block Electrical connection Valve Valve alternative Base block for sub base valves Field bus direct connection DeviceNet Sub base valve Blankingplate Base block for semi inlinevalves Semi inli...

Page 27: ...tive Base block for sub base valves 25 pin sub D multipinconnection MP connection Sub base valve Blankingplate Other possibilities 26 pin multipin plug strip for flat cable FL connection Tab 1 6 Compo...

Page 28: ...ve alternative Base block for semi inlinevalves 25 pin sub D multipinconnection Semi inlinevalve Blankingplate Other possibilities 26 pin multipin plug strip for flat cable Tab 1 7 Components of the C...

Page 29: ...ction Valve Valve alternative Base block for sub base valves Plug inconnection Sub base valve Blankingplate Base block for semi inlinevalves Semi inlinevalve Tab 1 8 Components of the CPA SC valve ter...

Page 30: ...on Valve Valve alternative Base block for sub base valves Horizontal connector Sub base valve Blankingplate Base block for semi inlinevalves Semi inlinevalve Tab 1 9 Components of the CPA SC valve ter...

Page 31: ...use of valve plates which are each fitted with two valve solenoid coils 1 1 10 10 16 Maximum number of valve solenoid coils which can be controlled 32 32 20 20 32 1 On CPA SC valve terminals with HC...

Page 32: ...cal connection Valve Individuallocation base block for sub bases or semi inlinevalves Plug in connection with adapter PI connection Sub base valve with PI connection Semi inlinevalve with PI connectio...

Page 33: ...ure via connections 1 or connection 5 With vacuum operation operating pressure via connection 1 vacuum at connection 5 e g for vacuum switching with reject pulse See also the instructions in the chapt...

Page 34: ...es Valve terminal with semi inline valves 2 1 2 3 4 1 Manual override covers optional 2 Manual override turning locking or non locking depending on pilot solenoid 3 Work connections 2 4 on the sub bas...

Page 35: ...the pilot solenoids 4 Groove for identification label optional 5 Connection for CP module 6 Connection for power supply 7 Earth connection 8 Connection for field bus 9 Field bus LEDs PS Power System...

Page 36: ...inal with MP or FL connec tion 1 3 2 4 1 Yellow LED signal status displays of the pilot solenoids 2 Groove for identification label optional 3 Clip with inscription field optional 4 Multipin connectio...

Page 37: ...e found on the CPA SC valve terminal with PI connection 1 2 4 3 1 Yellow LED signal status displays of the pilot solenoids 2 Groove for identification label optional 3 Identification clips optional 4...

Page 38: ...ments can be found on the CPA SC valve terminal with HC connection 1 2 3 1 Yellow LED signal status displays of the pilot solenoids 2 Horizontal connector and connecting cable with plug 3 Identificati...

Page 39: ...4 Base block with sub base valve Base block with semi inline valve 2 1 2 3 4 1 Manual override cover optional 2 Manual override turning locking or non locking depending on pilot solenoid 3 Work conne...

Page 40: ...al with PI or HC connec tion PI connection HC connection 1 1 2 3 4 3 1 Yellow LED signal status display of the pilot solenoids 2 Plug in connection and connecting cable with plug 3 Identification clip...

Page 41: ...Fitting 2 1 Festo P BE CPASC EN en 0412b Chapter 2...

Page 42: ...2 1 2 1 General instructions on fitting and dismantling 2 4 2 2 Fitting variants 2 5 2 2 1 Fitting onto removing from a hat rail 2 6 2 2 2 Fitting onto a wall 2 8 2 3 CPA SC individual location base...

Page 43: ...This chapter deals with fitting and dismantling the following the CPA SC valve terminal onto from a fastening surface or hat rail the manual override caps Further information Special information on r...

Page 44: ...human beings and damage to property Before carrying out installation and or maintenance work switch off the following the compressed air supply the operating and load voltage supplies Please note Han...

Page 45: ...ear of the valve terminal so that it can be hung on the hat rail Note the specifications on vibration and shock for CPA SC valve terminals with field bus direct see appendix A Technical data Fitting o...

Page 46: ...e terminal onto a hat rail you will require the mounting kit CPASC1 BG NRH This kit contains 2 M4x10 screws and 2 clamping elements Fitting Proceed as follows 1 Make sure that the fastening surface ca...

Page 47: ...a hat rail 7 Turn the clamping unit so that it is upright to the hat rail Fasten the CPA SC valve terminal on both sides against tilting or sliding by tightening the retaining screw with 1 3 Nm Disma...

Page 48: ...2 2 Removing the CPA SC valve terminal from the hat rail 2 2 2 Fitting onto a wall The various base blocks have 4 holes for fitting the terminal onto a wall see Tab 2 2 Fitting Proceed as follows 1 M...

Page 49: ...5 mm x number of valve locations 33 mm 10 5 mm x number of valve locations 7 5 mm 10 5 mm x number of valve locations 8 mm 10 5 mm x number of valve locations 3 13 5 0 1 mm 13 5 0 1 mm 13 5 0 1 mm 12...

Page 50: ...n all supply lines see chapter 3 3 Secure a hanging mounted CPA SC valve terminal against falling down before you loosen it from the fastening sur face 4 Loosen the fastening screws in the base block...

Page 51: ...s see appendix A Make sure that there is sufficient space for connecting the supply lines and cables 2 Drill two mounting holes in the fastening surface dimensions see figure 1 Holes for horizontal fa...

Page 52: ...e caps optional You can fit covers onto the manual override if desired in order to protect it from unauthorized use Proceed as follows Clip the covers into the recesses of the manual override see figu...

Page 53: ...Installation 3 1 Festo P BE CPASC EN en 0412b Chapter 3...

Page 54: ...ompressed air 3 4 3 2 Pilot control of the valve solenoid coils pilot air 3 6 3 3 Pressure zone separation 3 8 3 4 Vacuum low pressure operation 3 12 3 5 Connecting the CPA SC valve terminal individua...

Page 55: ...uctions on pilot control of the valve solenoid coils with internal or external pilot air instructions on operating the valve terminals with pressure zone separation notes on vacuum low pressure operat...

Page 56: ...ral oils are used e g HLP oils as per DIN 51524 parts 1 to 3 or corresponding oils on the basis of polyal phaolefine PAO the residual oil content must not ex ceed max 5 mg m3 see ISO 8573 1 class 4 In...

Page 57: ...in the compressed air will reduce the service life of the valve terminal Use special oil OFSW 32 from Festo or the alternative oil listed in the Festo catalogue corresponding to DIN 51524 HLP32 basic...

Page 58: ...lve solenoid coils pilot air Caution Operate the CPA SC valve terminal only with compressed air or inert gases e g nitrogen Valve terminals with externally supplied pilot air For the pilot air connect...

Page 59: ...es when the CPA SC valve terminal is operated with several pres sure zones see Fig 3 1 External pilot air If the operating pressure lies below 3 bar or above 8 bar you must operate the pilot control o...

Page 60: ...exhaust channels 3 and 5 If the CPA SC valve terminal is also fitted with other valve plates operate the valve plates with Ident code I 2 x 2 2 way valves in a separate pressure zone with separ ate ex...

Page 61: ...re zone 2 5 Supply connections pressure zone 2 Fig 3 1 Exampe CPA SC 2 pressure zones pilot control with external pilot air Pilot control with internal pilot air Please note Note with the CPA SC valve...

Page 62: ...pply connections pressure zone 2 Fig 3 2 Example CPA SC with MP FL or DI connection 2 pressure zones pilot control with internally branched pilot air Please note Note with the CPA SC valve terminal wi...

Page 63: ...ched on the right with valve terminal with HC or PI connection 3 Pressure zone 1 4 Pressure zone 2 5 Supply connections pressure zone 2 Fig 3 3 Example CPA SC with PI or HC connection 2 pressure zones...

Page 64: ...ure supply via connection 1 The pressure zone is fitted only with the following valve plates 5 2 way valve single solenoid Ident code M 5 2 way valve double solenoid Ident code J 5 3 way valves Ident...

Page 65: ...perate these valve plates on CPA SC valve terminals which are also fitted with other valve plates in a separ ate pressure zone with separate exhaust channel 5 3 5 Connecting the CPA SC valve terminal...

Page 66: ...lease note Valves which control large volume actuators should be operated in a separate pressure zone You will then avoid problems with backpressure in exhaust channels 3 and 5 3 5 1 Connecting the pn...

Page 67: ...Connecting Proceed as follows 1 Push the tubing as far as possible in or over the tubing connection of the screw connector 2 If necessary pull locking ring 1 over the tubing connec tion or tighten th...

Page 68: ...mpensation hole L Variant with sub base valves Variant with semi inline valves 2 4 1 5 3 82 84 12 14 Pressure compensation hole L Only with base blocks which are intended for external pilot air Fig 3...

Page 69: ...re compensation hole L Variant with sub base valves Variant with semi inline valves 2 4 1 5 3 82 84 12 14 Pressure compensation hole L Only with base blocks which are intended for external pilot air F...

Page 70: ...ole L Base block with sub base valve Base block with semi inline valve 2 4 1 5 3 82 84 12 14 Pressure compensation hole L 2 4 Only with individual location base blocks which are intended for external...

Page 71: ...alves 3 or 5 G1 8 Screw connector on both sides of the base block for ducted exhaust for silencers Exhausting the pilot air 82 84 M5 Screw connector on both sides of the base block for ducted exhaust...

Page 72: ...ilot air 12 14 and 82 84 M3 Screw connector on the base block Pressure compensation L M3 Screw connector on the base block Depending on what you have ordered the CPA SC may already be fitted with QS s...

Page 73: ...return valves 3 5 2 Loosening the pneumatic connections Warning Pneumatic tubing still under pressure may perform sudden uncontrolled movements when disconnected thereby causing injury to human beings...

Page 74: ...out of the screw connector 4 Seal non required screw connections with blanking plugs 3 1 2 3 Fig 3 9 Disconnecting the tubing 3 5 3 Connecting the electric cables Warnung Use only PELV circuits as per...

Page 75: ...g voltage for the valves and output modules compressed air supply Caution Long signal cables reduce the immunity to interference Make sure that the maximum permitted signal cable length of 10 m is not...

Page 76: ...tion Attach the relevant cable see table to the horizontal connector of the valve plate 1 Cable with plug 2 HC connection 1 2 Fig 3 10 Fitting the HC connecting cable 2 Valve terminal with PI or HC co...

Page 77: ...MP or FL connection The multipin connection can be turned 90 Proceed as follows 1 Press and hold the locking lug on the multipin connection see figure 2 Swing the multipin plug into the desired positi...

Page 78: ...large cross sectional area between the CPA SC valve terminal and the earth potential earthed fastening surface or earthed machine stand You can thereby avoid faults due to electromagnetic influences a...

Page 79: ...ssigned with blanking plates are not wired and do not therefore occcupy any addresses 1 3 5 7 9 11 13 15 0 2 4 6 8 10 12 14 16 17 18 19 1 3 4 2 5 6 1 Valve plates with two valve solenoid coils occupy...

Page 80: ...alve terminal with MP connection Detailed instructions on addressing can be found in the leaflet supplied with the product CPA SC valve terminal with DI connection Detailed information on addressing c...

Page 81: ...Commissioning 4 1 Festo P BE CPASC EN en 0412b Chapter 4...

Page 82: ...eral instructions 4 4 4 1 1 Before commissioning 4 4 4 1 2 Pressure build up of the complete supply 4 4 4 2 Manual override 4 7 4 3 Testing the valves and the valve actuator combination 4 9 4 4 LED di...

Page 83: ...CPA SC valve terminal The following belong here instruction on pressure build up in the complete supply operating the manual overrides testing the valves and the valve actuator combination assigning...

Page 84: ...er of valves is fitted when the maximum operating voltage is applied when the solenoid coils are constantly stressed Note the following instructions on building up the complete pressure supply 4 1 2 P...

Page 85: ...itched on via a safety start up valve slow build up of pressure and when there are electric signals e g after EMERGENCY STOP This may cause damage to the machine or system and even injury to human bei...

Page 86: ...electric signal The slow build up of pressure in the complete system then has no ef fect on the actuator The actuator would react suddenly e g a cylinder would extend or retract suddenly depending on...

Page 87: ...slowly Tab 4 1 Effects of slow start up pressurization 4 2 Manual override You should use the manual override principally when commis sioning the pneumatic system in order to check the functional abil...

Page 88: ...al overrides to the valve solenoid coils is as follows 1 Manual overrides for valve solenoid coils 12 2 Manual overrides for valve solenoid coils 14 12 12 12 12 12 12 12 12 14 14 14 14 14 14 14 14 14...

Page 89: ...ilot air Proceed as follows when commissioning the CPA SC valve terminal Commissioning variants Activity Preliminarycheck of the pneumatictubing Checking the valve actuator combination by means of the...

Page 90: ...oltage Manual override actuations which are in the switched posi tion can cause actuators to perform sudden unexpected movements during commissioning These could lead to injury to human beings and dam...

Page 91: ...ual override Actuate the manual override with max 25 N 3 Make sure that all valves are in the basic position before commissioning the valve terminal Caution Valves with manual overrides in the switche...

Page 92: ...witches Please note Do not turn the plunger when it is pressed down Otherwise the manual override will not lock The valve assumes the switch position Hold the plunger of the manual override pressed do...

Page 93: ...5 mm until the valve switches Then turn the plunger in a clockwise direction as far as possible The valve assumes the switch position Leave the plunger in position remains in the switch position Then...

Page 94: ...hown in the following diagram The assignment of the LED to the relevant manual override is left hand LED to rear manual override 12 right hand LED to front manual override 14 1 LED and manual override...

Page 95: ...Basic position Logical 0 no signal yellow alight Switch position Logical 1 signal present Basic position Logical 1 but the operating voltage of the outputs lies below the permitted tolerance range 21...

Page 96: ...ine connections Check the tubing Valve or pneumatic system does not react as expected does not react Check the tubing Check the electric cables Reset the manual override at the basic position After sw...

Page 97: ...ith centrally ducted exhaust are used Two or more pressure zones Limiting the pressure zones by fitting separator elements in the relevant channels Conversion possible at a later date see chapter 5 Va...

Page 98: ...4 Commissioning 4 18 Festo P BE CPASC EN en 0412b...

Page 99: ...Maintenance and conversion 5 1 Festo P BE CPASC EN en 0412b Chapter 5...

Page 100: ...5 Maintenance and conversion 5 1 5 1 General precautionary measures 5 4 5 2 Dismantling the CPA SC valve terminal 5 4 5 3 Replacing CPA SC components 5 6 5 3 1 Replacing valve plates or blanking plate...

Page 101: ...Contents of this chapter This chapter deals with the conversion or replacement of the following components the replacement of blanking plates and valve plates adding pressure zones Further informatio...

Page 102: ...lve terminal If the CPA SC valve terminal is easily accessible it will not be necessary to dismantle it to replace or remove components on the valve locations If it is necessary to dismantle the valve...

Page 103: ...the plug in plugs out of the guide in the base block HC connection Mark all connecting plugs on the valve plates Press on the locking lugs of the connect ingplugs Pull the plugs carefully away from th...

Page 104: ...coils the relevant valve location supports If you wish to replace a blanking plate with a valve plate with two valve solenoid coils If you wish to replace a valve plate with one valve sole noid coil w...

Page 105: ...trolled 5 3 1 Replacing valve plates or blanking plates You must carry out the following tasks before a valve plate can be removed from the CPA SC valve terminal with HC connection 1 Mark the HC conne...

Page 106: ...en 0412b Fig 5 1 Removing valve plates Fittign the components 1 Check the seal for damage 2 If necessary replace damaged seals 3 Make sure that the seal is fitted correctly It must lie in the recess i...

Page 107: ...on nection on the relevant valve plate 5 3 2 Fitting dismantling the pressure zone separator element The CPA SC valve terminal can be operated with maximum 2 pressure zones The pressure zones are form...

Page 108: ...r fixing pins 5 Fixing pins With a notch for channel 1 with 3 notches for channel 3 with 5 notches for channel 5 Fig 5 2 Components of the channel separator set Please note In the fitting procedure de...

Page 109: ...to the right on the base block 2 Remove the valve plate after the position of which the channel is to be separated in the example on VP 5 3 In order to facilitate fitting remove also the valve plate i...

Page 110: ...1 Recesses in the separator element 2 Separator elements 1 2 Fig 5 4 Fitting pressure zone separator elements 5 Pull the fixing pin by the projecting dismantling aid out of the hole in the example in...

Page 111: ...identifica tion plate onto the relevant position in the base block Please note Note that due to the separator element in the following valve locations the valve plates have up to 20 less flow the valv...

Page 112: ...5 Maintenance and conversion 5 14 Festo P BE CPASC EN en 0412b...

Page 113: ...Technical appendix A 1 Festo P BE CPASC EN en 0412b Appendix A...

Page 114: ...A Technical appendix A 2 Festo P BE CPASC EN en 0412b Contents A Technical appendix A 1 A 1 Technical data A 3 A 2 Festo accessories A 12 A 3 Overview of the valve plates A 13...

Page 115: ...ials Base block Valve plate Seals AL GD AL PPS ST PA GF NBR HNBR FPM Vibration and shock Vibration Tested as per DIN IEC 68 EN 60068 parts 2 6 Fastening to a hat rail Fastening to a wall Shock Tested...

Page 116: ...Base block basic weight of CPA SC valve terminal with MP FL connection with HC PI connection with DI connection Base block additional weight per valve location per valve plate per blanking plate Indiv...

Page 117: ...control With pilot air branched inter nally from connection 1 With externally supplied pilot air Pressure range Valve plates with 2 x 2 2 2 x 3 2 1 x 3 2 5 2 or 5 3 way valve Ident code I J N K X M B...

Page 118: ...ge for valves with external pilot air 3 Operating pressure at supply connection 1 bar 0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 1 2 3 Fig A 1 Diagram Pressure of external pilot air as a factor of the...

Page 119: ...Identification Code I C 3 Valves with PI connection for fitting onto base blocks with MP FL PI or DI connection Tab A 5 Standard rated flows for sub base valves Pneumatics Standardrated flows 1 for s...

Page 120: ...blocks with MP FL PI or DI connection Tab A 7 Standard rated flows for semi inline valves with QS3 work connections Pneumatics Standardrated flows 1 for semi inline valves with QS4 work connections Id...

Page 121: ...with MP FL PI or DI connection Tab A 9 Standard rated flows for semi inline valves with QA work connections Pneumatics Standardrated flows 1 for semi inline valves with QB work connections Ident code...

Page 122: ...y valve Ident code K N X 5 2 way valve single solenoid Ident code M 5 2 way valve double solenoid Ident code J 5 3 way valve Ident code B E and G 10 10 10 10 10 20 at 0 20 20 25 Connections Compressed...

Page 123: ...shock protection against direct and indirect contact as per IEC DIN EN 60204 1 By PELV power unit Protected Extra Low Voltage Operatingvoltage Tolerance Minimum switch off time Minimum requirement of...

Page 124: ...valve solenoid coils KMP6 25 P 12 KMP6 25 P 20 CPA SC valve terminal with FI connection Ribbon cable Plug connector for ribbon cable Ribbon cable with round conductors in grid 1 27 mm cable cross sect...

Page 125: ...ation Work air can be supplied separately at connection 5 with vacuum operation supply operating pressure via connection 1 supplyvacuum via connection 5 vacuum is switched to connection 4 via solenoid...

Page 126: ...rn no pressure supply via connection 1 external vacuum compressed air supply via connection 4 82 84 12 14 5 3 1 4 2 12 14 Ident code N Function two single solenoid 3 2 way valves open in basic positio...

Page 127: ...ouble solenoid valve 82 84 12 14 5 3 1 4 2 14 Ident code M Function single solenoid 5 2 way valve spring return Please note On a CPA SC valve terminal with MP or FL connec tion this valve occupies 2 a...

Page 128: ...12 14 Ident code B Function 5 3 way valves pressurized in mid position 82 84 12 14 5 3 1 4 2 12 14 Ident code G Function 5 3 way valve in mid position blocked 82 84 12 14 5 3 1 4 2 12 14 Ident code E...

Page 129: ...Index B 1 Festo P BE CPASC EN en 0412b Appendix B...

Page 130: ...B Index B 2 Festo P BE CPASC EN en 0412b Contents B Index B 1...

Page 131: ...pressed air Demands A 4 Requirements 3 4 Connecting variants electrical VI VII VIII IX 1 6 pneumatical 1 5 Connections Code 3 19 3 20 Electrical Individual location base block with PI HC connection 1...

Page 132: ...3 With PI connection Connecting the valve solenoid coils 3 23 D Designated use V DI connection 1 7 1 19 Display elements Individual location base block with PI HC connection 1 24 Valve terminal with D...

Page 133: ...tructions X Individual location base block 1 16 L Low pressure operation 3 12 4 17 M Manual override 1 18 1 23 Designs 4 7 Non locking 4 12 Turning locking 4 13 Materials A 3 Medium A 5 Compressed air...

Page 134: ...trical connections 1 6 Pneumatic 1 5 P PI connection 1 9 1 21 Pictograms XI Pilot control Pressure range A 5 Pilot pressure A 6 External auxiliary pilot air 3 7 Internal auxiliary pilot air 3 7 Pneuma...

Page 135: ...A 8 A 9 Start up pressurization 4 7 Supply pressure Internal external auxiliary pilot air 3 7 Switching status display 4 15 T Target group V Text markings XI Tightening torques A 3 Tubing 3 15 V Vacu...

Page 136: ...B Index B 8 Festo P BE CPASC EN en 0412b W Weights A 4...