3. Installation
3−15
Festo P.BE−CPASC−EN en 0412b
Laying the tubing
Please note
·
If necessary, place a suitable sealing ring under the
M5/M7 screw connectors or silencers, in order to avoid
leakage.
If angled connectors or multiple distributors are used, the air
flow will usually be reduced.
Connecting
Proceed as follows:
1. Push the tubing as far as possible in or over the tubing
connection of the screw connector.
2. If necessary, pull locking ring
1
over the tubing connec
tion or tighten the clamping screw
2
.
3. For reasons of clarity bundle the tubing together with:
tubing straps or
multiple hose holders.
1
2
Fig.3/4:
Fitting the tubing
Position of the pneumatic connections
The position of the pneumatic connections depends on the
variant of the CPA−SC (see following figures).
Summary of Contents for Smart cubic CPA-SC Series
Page 2: ......
Page 4: ...Contents and general instructions II Festo P BE CPASC EN en 0412b...
Page 16: ...Contents and general instructions XIV Festo P BE CPASC EN en 0412b...
Page 17: ...Summary of components 1 1 Festo P BE CPASC EN en 0412b Chapter 1...
Page 41: ...Fitting 2 1 Festo P BE CPASC EN en 0412b Chapter 2...
Page 53: ...Installation 3 1 Festo P BE CPASC EN en 0412b Chapter 3...
Page 81: ...Commissioning 4 1 Festo P BE CPASC EN en 0412b Chapter 4...
Page 98: ...4 Commissioning 4 18 Festo P BE CPASC EN en 0412b...
Page 99: ...Maintenance and conversion 5 1 Festo P BE CPASC EN en 0412b Chapter 5...
Page 112: ...5 Maintenance and conversion 5 14 Festo P BE CPASC EN en 0412b...
Page 113: ...Technical appendix A 1 Festo P BE CPASC EN en 0412b Appendix A...
Page 129: ...Index B 1 Festo P BE CPASC EN en 0412b Appendix B...
Page 130: ...B Index B 2 Festo P BE CPASC EN en 0412b Contents B Index B 1...
Page 136: ...B Index B 8 Festo P BE CPASC EN en 0412b W Weights A 4...