4
Commissioning
38
Festo – P.BE-CPX-CTEL-EN – 1601b – English
4.7.2
Observe signal statuses (monitoring)
You can use the operator unit (CPX-MMI) to observe the signal statuses of the connected (and recognised)
I-Port devices.
2:CTEL
Monitoring/Forcing (M)
Diagnostics (D)
Parameters (P)
Fail Safe (F)
Module Data (MD)
2:CTEL:M
Process state
Input Ch 0: 32
Input Ch 1: 0
Input Ch 2: 16
…
Output Ch 0: 4
Output Ch 1: 0
Output Ch 2: 0
…
1
2
1
Channels of the device at the first assigned
I-Port (here input module)
2
Channels of the devices at further assigned
I-Ports (here output module)
Fig. 4.2
The “Force” function can also be called up via the “Monitoring/Forcing (M)” menu. This function allows
you to force signal statuses during the commissioning phase for test purposes.
The representation of the I-Port devices also applies accordingly to the “Idle mode” and
“Fail safe” functions.