System overview, CTEL system
Festo – P.BE-CPX-CTEL-EN – 1601b – English
15
2.4
Address space
The CTEL master module can make available a total of up to 32 bytes for inputs and 32 bytes for outputs.
The precise number of the I/O bytes made available depends on the requirements of the connected devices.
I/O configuration presettings
The address space that the CTEL master module makes available and assigns accordingly in the CPX
system can be configured according to different presettings (
è
Tab. 2.4). These presettings correspond
to the selection options that are supported within the configuration files for the respective host system
(
è
3.6 Connection with the host system).
For the CTEL master module there are 3 presettings available for operation as a “pure input module”,
a “pure output module” and for “mixed operation”. In addition, there is also a setting for operation
without connected devices.
Operation as
Unused module
(no devices connected)
0 bytes
0 bytes
Pure output module
0 bytes
8 bytes
0 bytes
16 bytes
0 bytes
24 bytes
0 bytes
32 bytes
Pure input module
8 bytes
0 bytes
16 bytes
0 bytes
24 bytes
0 bytes
32 bytes
0 bytes
Mixed operation
8 bytes
8 bytes
16 bytes
16 bytes
24 bytes
24 bytes
32 bytes
32 bytes
1)
Related to the complete CTEL master module
Tab. 2.4
The I/O lengths listed here are the sum of the bytes available for all I-Ports together.