3
Installation
24
Festo – P.BE-CPX-CTEL-EN – 1601b – English
Current consumption from U
EL/SEN
of the CPX terminal
Internal electronics current consumption, CTEL master module
approx.
0.06 A
Internal electronics current consumption, device I-Port 1
_____ A
Sensor current consumption at I-Port 1
+_____ A
Sum of the current consumption at I-Port 1 (max. 1.6 A)
=_____ A
+_____ A
Internal electronics current consumption, device I-Port 2
_____ A
Sensor current consumption at I-Port 2
+_____ A
Sum of the current consumption at I-Port 2 (max. 1.6 A)
=_____ A
+_____ A
Internal electronics current consumption, device I-Port 3
_____ A
Sensor current consumption at I-Port 3
+_____ A
Sum of the current consumption at I-Port 3 (max. 1.6 A)
=_____ A
+_____ A
Internal electronics current consumption, device I-Port 4
_____ A
Sensor current consumption at I-Port 4
+_____ A
Sum of the current consumption at I-Port 4 (max. 1.6 A)
=_____ A
+_____ A
Sum of the current consumption of the CTEL system (max. 9 A
=_____ A
1)
è
Manufacturer's specifications
2)
Limit value within a voltage zone, minus the other consumers within the voltage zone
Tab. 3.1
An additional power supply of 1.6 A per I-Port can be made available through the load
voltage supply U
VAL
.