Proceed as follows:
Dismantling
1. Loosen the CPA valve terminal from the mounting
surface (see section "Dismantling the CPA valve ter-
minal" in this chapter).
2. Unclamp the CPA valve terminal. To do this loosen
the fastening screws of all the components in the
valve locations by two turns. Dismantle all the com-
ponents which you wish to remove from the valve
locations (see section "Replacing valve, reserve and
additional pressure supply plates" in this chapter).
3. Dismantle the appropriate end plate and pull the
valve locations away from the tie rods. If necessary,
remove also the appropriate valve locations (see
section "Replacing the end plate, sub-base or man-
ifold block" in this chapter).
4. Adapt the tie rods to the new number of valve
locations (see tables for the tie rod components and
Fig. 5/13).
PLEASE NOTE
When extending the CPA valve terminal with tie rod
extension, make sure that the latter is flush with the
basis tie rod. Use the tie rod extension only for 2
additional valve locations. Further tie rod extensions
are not permitted.
5. Maintenance and conversion
CPA... 9808A
5-27
Summary of Contents for CPA VI Series
Page 2: ......
Page 4: ...Order no 173 515 Title MANUAL Designation P BE CPA GB II CPA 9808A...
Page 15: ...Chapter 1 System summary 1 System summary CPA 9808A 1 1...
Page 29: ...Chapter 2 Fitting 2 Fitting CPA 9808A 2 1...
Page 35: ...Kapitel 3 Installation 3 Installation CPA 9808A 3 1...
Page 54: ...3 Installation 3 20 CPA 9808A...
Page 55: ...Chapter 4 Commissioning 4 Commissioning CPA 9808A 4 1...
Page 69: ...Chapter 5 Maintenance and conversion 5 Maintenance and conversion CPA 9808A 5 1...
Page 97: ...Technical appendix A Technical appendix CPA 9805NH A 1...