LED displays of the valves
There is a yellow LED for each valve solenoid coil. This
LED shows the switching status of the valve solenoid
coil.
The diagram below shows the position of the LEDs for
the manual override actuations on CPA valve terminals
with MP, CP or AS-i connections.
Note the assignment of the LEDs to the appropriate
manual override:
– left-hand LED in the electrical bridge for the front ma-
nual override (12)
– right-hand LED in the electrical bridge for the rear
manual override (12)
1
2
LED and manual overrides for pilot solenoids 14
LED and manual overrides for pilot solenoids 12
Fig. 4/5: Assignment of LEDs to the manual overrides on CPA valve
terminals with MP, CP and AS-i connections
14
14
12
14
12
14
12
14
12
14
12
2
1
4. Commissioning