2.1.1 Fitting onto a wall
Proceed as follows:
1. Make sure that the mounting surface can support
the CPA valve terminal.
2. Make sure that there is sufficient space for connect-
ing the supply cables and pneumatic tubing.
3. Bore four holes in the mounting surface (see diag-
ram for distance between holes).
CPA10 terminal
CPA14 terminal
1
2
3
4
66.3 mm
23 mm
10.6 mm x number of sub-
bases
4 holes for fitting onto feet
76.1 mm
26 mm
14.6 mm x number of sub-
bases
4 holes for fitting onto feet
Fig. 2/4: Position of the fastening holes
4. Fasten the CPA valve terminal onto the mounting
surface with four M4 screws of sufficient length
(tightening torque 0.8 Nm).
1
2
3
2
4
4
4
2. Fitting
2-4
CPA... 9808A