A. Technical appendix
A−8
Festo P.BE−CPASC−EN en 0808c
Pneumatics
Standard rated flows for sub−base valves
1)
Ident. code
2)
Valve with
PI connection
3)
Valve with
HC connection
Valve on individual
location base block
M, J, N
150
120
170
K, B, G, E
120
120
150
X
100
85
−−−
I
140
120
140
1)
Standard rated flows in [I/min], (±15 %), values apply to pressurizing and exhausting
2)
Ident. code =
I
dentification
c
ode (I.C.)
3)
Valves with PI connection for fitting onto base blocks with MP, FL, PI or DI connection
Tab.A/5:
Standard rated flows for sub−base valves
Pneumatics
Standard rated flows
1)
for semi−inline valves with M5 work connections
Ident. code
2)
Valve with
PI connection
3)
Valve with
HC connection
Valve on individual
location base block
M, J, N, B
180
180
180
K, G, I
150
150
150
E
180
170
170
X
120
120
−−−
1)
Standard rated flows in [I/min], (±15 %), values apply to pressurizing and exhausting
2)
Ident. code =
I
dentification
c
ode (I.C.)
3)
Valves with PI connection for fitting onto base blocks with MP, FL, PI or DI connection
Tab.A/6:
Standard rated flows for semi−inline valves with M5 work connections
Summary of Contents for CPA-SC Series
Page 2: ......
Page 4: ...Contents and general instructions II Festo P BE CPASC EN en 0808c...
Page 17: ...Summary of components 1 1 Festo P BE CPASC EN en 0808c Chapter 1...
Page 41: ...Fitting 2 1 Festo P BE CPASC EN en 0808c Chapter 2...
Page 55: ...Installation 3 1 Festo P BE CPASC EN en 0808c Chapter 3...
Page 85: ...Commissioning 4 1 Festo P BE CPASC EN en 0808c Chapter 4...
Page 102: ...4 Commissioning 4 18 Festo P BE CPASC EN en 0808c...
Page 103: ...Maintenance and conversion 5 1 Festo P BE CPASC EN en 0808c Chapter 5...
Page 116: ...5 Maintenance and conversion 5 14 Festo P BE CPASC EN en 0808c...
Page 117: ...Technical appendix A 1 Festo P BE CPASC EN en 0808c Appendix A...
Page 133: ...Index B 1 Festo P BE CPASC EN en 0808c Appendix B...
Page 134: ...B Index B 2 Festo P BE CPASC EN en 0808c Contents B Index B 1...