3.4
Address assignmentof the valves
CPA−SC valve terminal with PI or HC connection
·
Addresses should be assigned in ascending consecutive
order.
·
Counting begins from left to right, on the individual valve
plates from the front to the rear (see Fig.3/13).
·
The single−solenoid valve with Ident. code M (5/2−way
valve) or X (3/2−way valve) occupies one address; all
other valves occupy two addresses.
·
Valve locations assigned with blanking plates are not
wired and do not therefore occcupy any addresses.