CESA-GW-AS-CO Description
34
Store+Run
Pressing "OK" stores the detected configuration and the detected slaves on the
AS-i network as the active configuration. The gateway then switches to the pro-
tected operating mode.
Store + Prj Mode
Pressing "OK" stores the detected configuration and the detected slaves on the
AS-i network as the active configuration. The gateway remains in configuration
mode.
Pressing "ESC" leaves this menu and switches back to the main menu.
6.6
SLAVE ADR TOOL
Main menu ||
SLAVE ADR TOOL
||
This function enables setting and changing the addresses of both new and al-
ready configured AS-i slaves. This function replaces the handheld AS-i address
programming device.
Pressing the OK button continues with the actual test, ESC cancels the process.
Now the new slave can be connected to the AS-i network. After connecting, the
current address of the slave is displayed as "OLD ADDRESS"and the message
"CONNECT NEW SLV" disappears.
To assign a new address to the slave the menu entry "NEW ADDRESS" must be
selected. Afterwards the new address can be selected by using the arrow but-
tons. The selected address is assigned by selecting "PRG" on the menu and
pressing the OK button.
If an error occurs while addressing a slave, one of the following error messages is
displayed for about 2 seconds:
SLAVE ADR TOOL
CONNECT NEW SLV
OLD ADDRESS
NEW ADDRESS
PRG
SLAVE ADR TOOL
CONNECT
OLD ADDRESS 21A
NEW ADDRESS 03B
PRG
Failed: SND: slave with old address has not been detected.
Failed: SD0: slave with address 0 already exists.
Failed: SD2: chosen slave address already exists.
Failed: DE: AS-i slave address cannot be deleted.